Copyright © 2017 Symantec Corp. All rights reserved. Symantec, the Symantec Logo, the Checkmark Logo, Blue Coat, and the Blue Coat logo are trademarks or registered trademarks of Symantec Corp. or its affiliates in the U.S. and other countries. Other names may be trademarks of their respective owners. This document is provided for informational purposes only and is not intended as advertising. All warranties relating to the information in this
document, either express or implied, are disclaimed to the maximum extent allowed by law. The information in this document is subject to change without notice. Part Number: 231-03313 Rev A.0
THE DOCUMENTATION IS PROVIDED “AS IS” AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT, ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID. SYMANTEC CORPORATION SHALL NOT BE LIABLE FOR INCIDENTAL OR
CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, PERFORMANCE, OR USE OF THIS DOCUMENTATION. THE INFORMATION CONTAINED IN THIS DOCUMENTATION IS SUBJECT TO CHANGE WITHOUT NOTICE. SYMANTEC CORPORATION PRODUCTS, TECHNICAL SERVICES, AND ANY OTHER TECHNICAL DATA REFERENCED IN THIS DOCUMENT ARE SUBJECT TO U.S. EXPORT CONTROL AND SANCTIONS LAWS, REGULATIONS AND
REQUIREMENTS, AND MAY BE SUBJECT TO EXPORT OR IMPORT REGULATIONS IN OTHER COUNTRIES. YOU AGREE TO COMPLY STRICTLY WITH THESE LAWS, REGULATIONS AND REQUIREMENTS, AND ACKNOWLEDGE THAT YOU HAVE THE RESPONSIBILITY TO OBTAIN ANY LICENSES, PERMITS OR OTHER APPROVALS THAT MAY BE REQUIRED IN ORDER TO EXPORT, RE-EXPORT, TRANSFER IN COUNTRY OR IMPORT AFTER DELIVERY TO YOU.
Page 2
PS-S200, PS-S400, PS-S500 Quick Start Guide
06
Perform a Graceful Shutdown
Before proceeding to rack-mounting the appliance, log in to the PacketShaper CLI and perform
a graceful shutdown of the appliance.
To perform a graceful shutdown:
a.
Log in to the PacketShaper CLI (see
Step 4
).
b.
Enter:
shutdown
Warning:
Do not power off the appliance with the soft power switch or by removing the power
cables! Abruptly removing power can result in irreparable data loss. Always use the
shutdown
command from the CLI to power off the appliance.
07
Rack-Mount the Appliance
The slide-rail mounting kit included with the PS-S400 and PS-S500 appliances (available as an
option for PS-S200 appliances) allows the appliance to be rack-mounted in a two- or -four-post
equipment rack. The slide-rail kit includes the following parts:
Note:
To rack-mount the appliance, you may need an M4 nut driver or adjustable wrench, #2
Phillips head screwdriver, and rack screws.
Note:
The following procedure documents how to install the appliance in a four-post equipment
rack. For comprehensive information on rack-mounting the appliance, including other
configurations, see the S-Series Maintenance and Upgrade Guide at:
http://www.symantec.com/docs/DOC9795
To install the appliance in a four-post equipment rack:
a.
Disassemble the two slide-rail assemblies:
o
Fully extend each slide-rail by sliding out the inner rails until they reach the stop.
o
Release the white slide latches (toward the rear of the inner rails) and slide the inner rails
all the way out.
o
Slide-rails are symmetrical and can be used with either side of the chassis.
b.
Attach the two inner rails to the appliance:
o
Align each inner rail to the mounting posts on each side of the chassis. Slide the rail
toward either the front (
PS-S200
and
PS-S400
) or rear (
PS-S500
) of the chassis until
each of the mounting posts snap into place.
o
Secure the inner rails to the appliance with M3 screws:
•
For
PS-S200
and
PS-S400
appliances, use one M3 screw in the center of each rail.
•
For
PS-S500
appliances, use two M3 screws in each rail.
c.
For
PS-S200
and
PS-S400
appliances, install the two rack ears. Align them with the mounting
posts on the chassis sides near the front of the appliance and secure them with the included
fasteners.
d.
Assemble the two slide-rails and install them in the rack:
o
Loosely attach Rail_C to Rail_A. Secure the rails with three M3 screws inserted through
the slot in Rail_C and screwed into three holes in Rail_A. Make sure the screws are
equidistant from each other so the load will be evenly distributed on the rail. Do not yet
fully tighten the screws.
Note:
The precise attachment location of the screws will depend on how far Rail_C will
extend or retract to fit the rack. It may be necessary to remove Rail_C from Rail_A to
determine the proper installation length.
o
Install the assembled slide-rails in the rack:
•
Secure the front bracket for Rail_A to the outside front of the rack using two rack
screws. Do not yet fully tighten the screws. You will do so after the appliance is
installed in the rack.
•
Extend or retract Rail_C to align the rear bracket with the outside rear of the rack.
Secure the bracket with two M3 screws. Do not yet fully tighten the screws. You will
do so after the appliance is installed in the rack.
•
Tighten the side-mounting screws for Rail_C.
•
Verify the slide-rail assemblies are installed at the same rack eight.
e.
Install the appliance in the rack:
o
Align the inner rails attached to the appliance with the slide-rails in the rack and slide the
appliance half-way into the track.
o
Press the gray locking tabs on the inner rails to slide the appliance all the way into the rack.
o
Slide the appliance out of the rack, far enough to access the rack screws. Fully tighten
the rack screws for the front and rear brackets to secure the slide-rails to the rack.
o
Gently push the appliance all the way to the back of the rack and tighten the
thumbscrews on the retaining ears to prevent the appliance from sliding out.
f.
Reconnect the cables as documented in
Step 2—Connect Cables
and verify the appliance is
functioning as in
Step 3—Power On the Appliance and Verify LEDs
.
Technical Support
o
Contact Information
https://support.symantec.com/en_US/contact-support.html
o
MySymantec
Documentation
PacketShaper Software Documentation
o
http://www.symantec.com/docs/DOC9776
Appliance Documentation
o
S-Series Maintenance and Upgrade Guide
http://www.symantec.com/docs/DOC9795
o
S200 Series Safety and Regulatory Compliance Guide
http://www.symantec.com/docs/DOC10311
o
S400 Series Safety and Regulatory Compliance Guide
http://www.symantec.com/docs/DOC9996
o
S500 Series Safety and Regulatory Compliance Guide
http://www.symantec.com/docs/DOC10248
CAUTION:
Before rack-mounting the appliance:
o
Power off the appliance and disconnect all cables.
o
Verify that the weight of the system does not exceed the rack’s
fully populated weight limit. For more information, refer to the
manufacturer’s instructions included with the rack.
o
For weight stability, load the rack from the bottom up.
o
Read the “Rack Mount Warnings” section of the
Safety and
Regulatory Compliance Guide
.
o
Take adequate safety and grounding measures to avoid creating an
electrical shock hazard and to prevent bodily injury.
Rail_C
Rail_A
Inner Rail (2)
Rail_A (2)
Rail_C (2)
Rail_B (2)
(used only for 2-post racks)
M3 T-Type Screw (10)
M6 Screw (8)
M6 Cage Nut (8)
(optional)
Rail_C
Locking tab