Output Wiring:
Lamp wiring for dimming ballasts can differ significantly from non-dimming
ballasts and from other manufacturers dimming ballasts. Take care to connect lamp lead wires as
shown on the applicable ballast diagram.
Lamp Seasoning:
For optimal performance, fluorescent lamps may require seasoning for up to 12
hours prior to low temperature starting & low level dimming. Refer to NEMA LSD 23-2002 Lighting Systems Division: Recommended Practice —
Lamp Seasoning for Fluorescent Dimming Systems
Installation Notes
POWERSENSE
T8 DIM
Control Information
Catalog #
Date
Type
Project
Prepared by
Comments
SPECIFICATION DATA
Starting Method:
Programmed Rapid Start
Circuit Type:
Series
Lamp Frequency:
>40 kHz
Lamp CCF:
Less than 1.7
Starting Temp:
50°F/10°C minimum
for OCTRON T8 lamps
Input Voltage:
120-277V, ±10%
Input Frequency:
50/60 Hz
THD:
<10% @ Full Output
Power Factor:
>98% @ Full Output
UL Listed Class P, Type 1 Outdoor
CSA or C/UL Certified
70°C Max Case Temperature
FCC 47CFR Part 18 Non-Consumer
Class A Sound Rating
ANSI C62.41 Cat. A Transient Protection
Remote mounting (Max. wire length from
ballast case to lampholder) up to 8 feet
Performance Guide
Specifications
Data based on F32T8
High Efficiency
Electronic T8 Fluorescent Controllable Lighting Systems
Input
Input
Rated
Ballast
Initial
Input
System
Item
Voltage
Current
Lamp
Lumens
No. of
Factor
System
Power
Efficacy
Number
Description
(VAC)
(AMPS)
Type
(lm)
Lamps
(BF)
Lumens
(Watts)
(lm/W)
BEF
1
50705
QTP 1x32T8/UNV DIM-TC
120-277
0.27/0.12
FO32XP
3000
1
0.88
2640
30
88
2.93
0.05
150 8
50707
QTP 2x32T8/UNV DIM-TC
120-277
0.54/0.24
FO32XP
3000
2
0.88
5280
59/57
89/93
1.54
0.05
300 14
50714
QTP 3x32T8/UNV DIM-TCL 120-277
0.73/0.30
FO32XP
3000
3
0.88
7920
87/84
91/94
1.05
0.05 450 20
50716
QTP 4x32T8/UNV DIM-TCL 120-277
0.96/0.40
FO32XP
3000
4
0.88
10560
114/110
92/96
0.80
0.05
600 27
Products are all 10-pack. 1: Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (note: calculation based on lowest wattage value)
Item Number
50707 QTP 2 x 32T8 / UNV DIM-TC
QUICKTRONIC PROFESSIONAL
Number of Lamps (1, 2, 3, 4)
System Type - DIMMING/Case Size
Line Voltage (120-277V)
Primary Lamp Wattage
System Life / Warranty
QUICKTRONIC products are covered by QUICK
60+
®
, a comprehensive lamp and ballast
system warranty. For additional details, refer
to the QUICK 60+ warranty bulletin.
Data based on SYLVANIA OCTRON
®
lamps
shown. QUICKTRONIC
®
POWERSENSE
ballasts are also compatible with other
manufacturers equivalent lamp types that
meet ANSI specifications, including F17,
F25, F32 and the U-Bend equivalent lamps.
T8
POWERSENSE
®
High Efficiency
OSRAM SYLVANIA
National Customer
Service and Sales Center
1-800-LIGHTBULB
(1-800-544-4828)
www.sylvania.com
Black
White
Violet (+)
Grey (-)
Red
Red
Blue
Blue
LAMP 1
ELECTRONIC
BALLAST
BALLAST
ELECTRONIC
LAMP 1
LAMP 4
LAMP 3
LAMP 2
Yellow/Black
Yellow
Yellow
Red/Black
Red/White
Red
Red/White
Blue
Blue/White
Blue/White
Blue/Black
Grey (-)
Black
White
Violet (+)
Black
White
Violet (+)
Grey (-)
Red
Red
Blue
Blue
LAMP
1
Yel/Blk
Yellow
Yellow
LAMP 1
ELECTRONIC
BALLAST
LAMP 2
Dimensions:
1 & 2 lamp enclosure
Overall: 9.5" L x 1.68" W x 1.0" H (241 x 43 x 25 mm)
Mounting: 8.90" (226 mm)
Weight: 1.1 lbs each (500 g)
3 & 4 lamp enclosure
Overall: 16.7" L x 1.68" W x 1.0" H (425 x 43 x 25 mm)
Mounting:16.2" (411 mm)
Weight: 2.1 lbs each (950 g)
Wiring:
Leads Only
Mounting
Length
Length
Height
8.70 mm
S
lot
Width
Yel/Blk
Yellow
Yellow
Red/Black
Red/White
Red
Red/White
Blue
LAMP 1
LAMP 3
ELECTRONIC
BALLAST
Black
White
Violet (+)
Grey (-)
LAMP 2
Input & Control
Wiring Options:
POWERLINE CONTROL
LINE
BLACK
NEUTRAL
WHITE
INSULATE
UNUSED LEADS
VIOLET (+)
GREY
(-)
1 lamp
2 lamp
3 lamp
4 lamp
LOW-VOLTAGE CONTROL
VIOLET (+)
GREY
(-)
LINE
BLACK
NEUTRAL
WHITE
0-10V
DC
< 0.5
m
A
Class 1 or
Class 2
QUICKTRONIC POWERSENSE ballasts are
compatible with a wide range of low voltage (0-
10VDC) and power line fluorescent controllers
available from various manufacturers.
Low Voltage Control Specs: Ballast will source
up to 0.5mA for 0-10VDC control purposes.
May be wired as a Class 1 or Class 2 circuit-
consult Local and National Electrical Codes.
Power Line Control Specs: Specification-
grade fluorescent controls are available for
120V or 277V operation of controllable
analog electronic fluorescent ballasts.
Controls must be suitably rated for both the
type (e.g. Fluorescent Phasecontrol) and size
(e.g. 600W) of the connected load.
SYLVANIA, the system solution, , POWERSENSE, See the World in a New Light and PROStart are registered trademarks of OSRAM SYLVANIA Inc.
ELOGIC is a trademark of OSRAM SYLVANIA Inc. QUICKTRONIC is a registered trademark of OSRAM GmbH. NEMA Premium is a registered trademark of National Electrical Manufacturers Association.
©2010 OSRAM
SYL
V
ANIA
Specifications subject to change without notice.
Height
25.4mm
(1.0")
Mounting
411.3mm
(1
6
.2")
Length
425mm
(1
6
.7")
Width
43mm
(1.
6
8")