After completely reading instructions, confirm that all controls on stove are in the 
off position. plug the unit into a 15 amp, 120 volt outlet. 

OPERATION

Controls and switches are located on front panel inside the glass door.

o/i

: press this button into the “

i

” position for main power and flame effect. The 

indicator light will turn on. See below for other control switches.

: For heat function - press this switch while the 

o/i

 switch is in the “

i

” position. 

The indicator light will turn on.

: To adjust the temperature to your individual requirements, turn the thermostat 

dial to the right (clockwise) to increase the desired temperature and to the left for 
lower temperature. This thermostat control dial can only be used while the  
HEATING switch and 

o/i

 switches are in the “

i

” position.

when the heater reaches the desired temperature, the heater indicator light will 
turn off but the fan will continue to operate. Adjust this knob to restart the heater.

NotE:

 when the 

o/i

 switch is turned to the OFF position, the heater function will 

stop even though the switch may be in the “

i

”  position.

THERMOSTAT CONTROL

The heat output is controlled by the thermostat, according to the room tempera-
ture. Set the thermostat dial fully clockwise to the maximum position initially.
when the room is warm enough, reduce the setting by slowly turning the ther-
mostat dial anticlockwise until the heater just clicks off. This will then maintain the 
room temperature at the desired level.

cautioN

If you use this heater in conjunction with a thermal control, a programme control-
ler, a timer or any other device that switches on the heater automatically, remem-
ber to observe all safety warnings at all times.
The stove heater has a safety overheat protection. If the overheat protection trips, 
turn off the 

o/i

 switch and unplug the power cord from the receptacle.  It should 

reset automatically after 5 minutes.

WarNiNg

Disconnect power and unplug the power cord before attempting any maintenance 
or cleaning to reduce the risk of fire, electric shock or personal injury. The bulbs in 
your unit can become extremely hot. Allow at least 10 minutes between turning off 
the unit and removing the light bulbs to avoid the accidental burning of the skin.

FLAME EFFECT

The fire effect is created with the use of a 40 watt B-10 candelabra light bulb with an 
E-12 (small) socket base. The light bulb will have to be replaced from time to time 
when they burn out.
During normal operation the stove heater will always give you simulated flame 
function. If the intensity of flame suddenly increases, it means that the light bulb is 
going to burn out. 
Replace the light bulb immediately according to the instruction and do not operate 
the stove heater when the light bulb burns out or without the light bulb.

CHANGING THE LIGHT BULB

STEp 1:  Open the door of unit with the handle. 
STEp 2:  Loosen the 2 screws at the front of the log set inside the stove. Carefully lift  
 

the logset up far enough to access the light bulbs.  you will find 1 X 40w  

 

Type B-10 candelabra light bulb with E-12 socket base at the bottom. 

STEp 3:  Replace the burned out light bulb using a new 40 watt Type B-10 candela 
 

bra light bulb.

STEp 4: Reinstall the logset.
STEp 5: plug in the unit.

CLEANING

To clean unit first turn off controls on unit and unplug unit from power source.
To clean glass door; remove dust with clean dry cloth or to remove finger prints 
and other marks clean glass with clean damp cloth. Do not use abrasive cleaners or 
spray liquids on glass door surface.
Metal and metal painted parts should be cleaned with damp cloth. Do not use 
abrasive cleaners or spray liquids on these surfaces.

WARRANTY

Every electric stove is tested before it leaves the factory and it is guaranteed for 
one year. If the unit should fail to operate correctly within one year from the date 
of purchase, call customer service at 1-800-459-4409 EST. we will, at our discretion 
either repair or replace the unit. It will have to be returned to us freight prepaid and 
we will return the repaired or replaced unit to you freight prepaid. The company’s 
sole obligation is to repair or replace the unit.This warranty is void if in the opinion 
of Quality Craft the unit has been tampered with, altered, misused, damaged, 
abused or used with the wrong power source. Light bulbs are not covered by this 
warranty. The warranty is for homeowner use only and does not cover units used in 
commercial situations.

Imported by 

Quality craft

 

Laval, Quebec, Canada  H7S 2G7
1-800-459-4409 (EST)
www.qualitycraft.com
Made in China

Reviews: