5-2
L0201EA
Table 2: Initial Data (only 0004GP-0.47)
2. Software Reset
To reset software, press “5” button on the remote con-
trol unit for at least 5 seconds after pressing “CH
RETURN” button on the remote control unit.
3. Flicker Adjustment
When version of micro computer is 0004GP-0.47, the
following adjustment is necessary.
Adjustment Point:
VR481 (LCD Main CBA Unit)
Note:
Use service remote control unit
1. Enter the Service mode. (See page 5-1)
2. Press “2” button on the remote control unit.
The following screen appears.
3. If Flicker Adjustment is not fit, the screen become the
following.
4. Adjust VR481 so that flash stops.
SAIDO
5
128
C-SAIDO
228
H-P
8
50
C-H-P
50
V-P
9
40
C-V-P
40
COR(C/D1)
VOL
p
→
1
512
COG(C/D1)
VOL
p
→
2
512
COB(C/D1)
VOL
p
→
3
512
DR(C/D1)
VOL
p
→
4
128
DG(C/D1)
VOL
p
→
5
128
DB(C/D1)
VOL
p
→
6
128
COR(C/D2)
VOL
p
→
1
512
COG(C/D2)
VOL
p
→
2
512
COB(C/D2)
VOL
p
→
3
512
DR(C/D2)
VOL
p
→
4
128
DG(C/D2)
VOL
p
→
5
128
DB(C/D2)
VOL
p
→
6
128
7F
VOL
p
FF
LANGUAGE
SPA/FRA
STEREO TYPE
MTS
ACCESS CODE
OFF
BACK LIGHT
ON
HD
ON
2DVP
ES3
HRD
OFF
NCM
ON
ASPECT
OFF
ITEM
BUTTON
(on the service
remote control)
DATA
VALUE
D2-SAIDO
5
228
D3-SAIDO
228
NORMAL
0
74
DARK
150
ITEM
BUTTON
(on the service
remote control)
DATA
VALUE
VR481
LCD Main CBA Unit
FLASH
(Go and Off)