Sylvac 54-618-300 Quick Installation Manual Download Page 8

E

3.2  General unit configuration

Menus that allow you to configure the general parameters of your unit.

Examples:

Lock keyboard and touch screen, 

and define exceptions if required

Create measurement sequences and 

configure external contact

Save and load configurations and 

factory settings

8

Summary of Contents for 54-618-300

Page 1: ...D300S Universal display unit Swiss manufacturer of precision measuring instruments since 1969 Quick installation guide Firmware 1 21 E ...

Page 2: ......

Page 3: ...E 3 Index 1 Overall view 4 1 1 Description 5 2 Start up 6 3 User interface 6 3 1 Channel configuration 7 3 2 General unit configuration 8 4 Transfer and print data 9 5 Packaging 10 6 Accessories 10 ...

Page 4: ...E 1 Overall view Front Interface Back Connectors 4 12 7 1 3 4 6 5 17 16 18 9 2 13 10 11 8 14 15 ...

Page 5: ... button Master switch for the unit Connector for 24V power supply USB ports for SYLVAC instruments keyboard or mouse USB port D300S PC LAN port SYLVAC probe inputs 4 input module available Digital inputs outputs External contacts pedals limit switch etc Jack socket for speakers VGA output RS485 connector for connecting D302 D304 units RS232 input for SYLVAC instrument ...

Page 6: ...tion address is registered by the unit It is therefore vital not to switch it with other instruments If you disconnect the cable from the unit and use a different USB port when you next connect it the same channel will be reassigned to it 3 User interface Window showing details of channel X Active page indicator Select page X X Configure number of screens max 8 page General configuration Display t...

Page 7: ... control process In the vertical menu 2 buttons allow you to switch between basic and ad vanced configuration The area shown here allows you to select a predefined meas uring type e g A B A second field B will appear in order to allow you to select the instrument that will be associated with it List of instruments connected and available for selection 7 ...

Page 8: ... allow you to configure the general parameters of your unit Examples Lock keyboard and touch screen and define exceptions if required Create measurement sequences and configure external contact Save and load configurations and factory settings 8 ...

Page 9: ...l ter minal and external contacts Window that allows you to view trans fer and print the recorded values for each channel Select the information that will be printed when it is sent by pressing the pedal or external contacts Note Sequences of measurements or several channels can only be printed using a pedal or external contact A short press on the pedal sends the value in memory to the printer A ...

Page 10: ...Packaging Protective foam D300S display unit Packaging containing 24V 100 230V charger Power cable depending on country Pedal Outer box 1 2 3 4 The box contains the objects listed below It is important to retain this packaging in case the product needs to be re turned to the factory for servicing or repair 10 1 2 3 4 ...

Page 11: ...E Notes 11 ...

Page 12: ...We reserve the right to make changes Edition 2012 07 V1 0 Quick_Start_D300S_F 681 261 20 Ch du Closalet 16 CH 1023 Crissier E mail vente sylvac ch www sylvac ch ...

Reviews: