19
English
The boiler must be installed by qualified personnel.
Conica is available in the following models:
Model
Type
Category
Power rating
ie m
heating
B
11BS
24-28 kW
domestic hot water
ie FF m
heating
C
24-28 kW
domestic hot water
The boiler must be installed in compliance with local laws and
regulations.
Before installing, please bear in mind that:
- the boiler must not be located over a cooker or other cooking
equipment
- minimum clearances for maintenance work must be respected
- it is forbidden to leave flammable products in the room where the
boiler is installed
- heat sensitive walls (e.g. wooden walls) must be protected with
appropriate insulating material
The boiler is supplied standard with a support plate and cardboard
template (only ie FF m models).
Install as follows:
- prop the boiler supporting plate (
F
) against the wall and check that
it is perfectly horizontal using an air level
- mark 4 holes (6-mm diam.) to fix boiler support plate (
F
)
- check all measures are correct, and drill the wall by above-
mentioned drill diameter
- hook boiler to support plate.
Make hydraulic connections.
INSTALLER’S MANUAL
1.
BOILER INSTALLATION
Fig. 1
Conica ie m
Conica ie FF m
Fig. 2
Position and dimensions of hydraulic connections are specified in
figure 1:
A -
CH delivery
3/4”
B -
DHW outlet
1/2”
C -
Gas connection
3/4”
D -
DHW inlet
1/2”
E -
CH return
3/4”
support plate (F)
2.
HYDRAUILC CONNECTIONS
A
B
C
D
E
H
2
O - gas
400 (24 ie m)
450 (28 ie m)
180 (24 ie m)
180 (24 ie m)
205 (28 ie m)
205 (28 ie m)
400 (24 ie FF m)
450 (28 ie FF m)
180 (24 ie FF m)
180 (24 ie FF m)
205 (28 ie FF m)
205 (28 ie FF m)
H
2
O - gas
Summary of Contents for Conica ie FF m
Page 1: ...Manual de instalare utilizator Installation and use manual Conica ie m Conica ie FF m ...
Page 2: ......
Page 42: ...NOTE ...
Page 43: ......