14. Setting Single User Mode
The code lock can be set to single user mode by entering the code 8900. Ensure that the master
code determined has 4
fi
gures before setting the code lock to single user mode.
Input
Input
Note
MASTERCODE
* 8900 #
Single user mode active. Wait for 2-3 seconds until two con
fi
rmation sounds
are given after the # button was pressed.
When the code lock was set to single user mode, the code lock restarts automatically. The fac-
tory presettings are also loaded (except for master code; the personal master code is retained).
15. Setting Multi User Mode
The code lock can be set to multi user mode by entering code 8901.
Input
Input
Note
MASTERCODE
* 8901 #
Multi user mode is active. Wait for 2-3 seconds until two con
fi
rmation
sounds are given after the # button was pressed.
When the code lock was set to multi user mode, the code lock restarts automatically. The
factory presettings are also loaded (except for master code; the personal master code is
retained).
16. Programming and Handling the Code Lock (Handling Examples)
a) Programming Procedure
- The complete programming is performed on the front of the code lock. The settings made are
stored in an eprom. Thus, data will be retained even in case of a power outage.
- Before starting programming, you must call the programming mode. For this, the
master code
must be entered
fi
rst, and then the * button must be pressed.
MASTERCODE *
- When the code lock is in programming mode, you can make the required settings step by step.
For this, observe chapter "12. Programming Options (Quick Overview)".
- If you programmed an undesired setting (e.g. MASTERCODE 70 # instead of MASTERCODE 71 #),
you can perform the programming again to overwrite the previous setting.
- When all settings were made, the programming mode can be left. For this, press button *. The
settings made are, of course, saved.
b) Single User Mode Programming (Example)
Example settings overview:
- Single user mode
- Changing the factory master code 0000 to a personal master code 3289.
13
d) Kon
fi
guration der Ausgänge-Modi (OUTPUT 1, OUTPUT 2)
Location
Codeeingabe
Bestätigung
Anmerkung
40
1 bis 999
#
OUTPUT 1 in gegenwärtigem Modus von 1 bis 999 Sekun-
den
41
#
OUTPUT 1 in START/STOP Modus (Umschaltung)
42
#
OUTPUT 1 in START/STOP Modus (Umschaltung) mit be-
schleunigtem Code
50
1 bis 999
#
OUTPUT 2 in gegenwärtigem Modus von 1 bis 999 Sekun-
den
51
#
OUTPUT 2 in START/STOP Modus (Umschaltung)
52
#
OUTPUT 2 in START/STOP Modus (Umschaltung) mit be-
schleunigtem Code
e) Persönliche Sicherheit
Location
Codeeingabe
Bestätigung
Anmerkung
70
#
Nach 10 aufeinanderfolgenden falschen Codeeingaben
wird das Codeschloss für 30 Sekunden gesperrt.
71
#
Nach 10 aufeinanderfolgenden falschen Codeeingaben
wird der Duress-Ausgang auf Masseigeschalten.
72
5 bis 10
#
Festlegbar: Nach 5 bis 10 aufeinanderfolgenden falschen
Codeeingaben wird das Codeschloss für 15 Minuten ge-
sperrt. Die Sperrung kann jederzeit aufgehoben werden
durch Eingabe des Master-Codes.
76
00
#
Wegfall sämtlicher bisherig getätigten persönlichen Si-
cherheits-Einstellungen.
f) Door Forced-Open Alarm
Location
Codeeingabe
Bestätigung
Anmerkung
80
1
#
Door Forced-Open Alarm ist aktiviert
80
0
#
Door Forced-Open Alarm ist deaktiviert
g) Ausgangs-Aktivierungs-Signal festlegen
Location
Codeeingabe
Bestätigung
Anmerkung
81
1
#
Es wird ein 1-Sekunden langer Signalton wieder- gegeben
um der Person, welche einen gültigen Benutzer-Code ein-
gegeben oder den Egress- Taster betätigt hat, zu signali-
sieren nun die Tür zu öffnen.
81
0
#
Es ertönt ein zweimaliger Piepton bei erfolgreicher
Benutzer-Code-Eingabe.