6.3 Sensor coverage area

If the connected light is ≥ 60 W, the distance between light and sensor should be ≥ 60 cm.

1 - 1.8 m

10 m

190°

10 m

6.4 Motion sensor (PIR)

The passive infrared (PIR) motion sensor reacts to changes in temperature, e.g. when a person or animal
enters the detection area.

Position the sensor so the object moves across the detection area.

The correct installation height should be observed.

Do not point the sensor at radiators, lights, or objects with varying temperatures (e.g. electronic equip-
ment), and objects that may move due to the flow of air. This may trigger the sensor unintentionally.

Do not install the product behind glass.

Keep the sensor away from direct sunlight.

7 Operation

7.1 Switch settings "OFF / PIR / ON"

ON

: Connected load is always ON

PIR 

(auto): Power to the switch is automatically triggered by motion

detection. Triggering is affected by 

LUX

 (ambient light level) set-

tings.

OFF

: Connected load is OFF.

7.2 Switch-on time "TIME"

Control how long the connected the load stays ON after the sensor
is triggered.

If new motion is detected during the switched-on time, the timer will
restart.

See section “Technical data, PIR sensor time delay”.

Dial settings:

– Counter clockwise: decrease the duration.

– Clockwise: increase the duration.

7.3 Switching threshold "LUX"

You can adjust the switching threshold for different ambient light
levels.

– Counter clockwise: activates motion detection in darker condi-

tions.

– Clockwise: activates motion detection in brighter conditions.

7.4 Function test

Perform a function test to optimize the settings or check the product is functioning correctly.

Set the switch to 

ON

, the connected load should switch ON and stay on.

Set the switch to 

OFF

, the connected load should switch OFF.

Set the switch to 

PIR

 (auto) then walk across the detection area. The connected load should switch

on if movement is detected.

To test the PIR (auto) setting:

– Set the 

TIME

 dial to the minimum duration.

– Set the 

LUX

 dial to the highest (high ambient light) if testing in daylight.

Fine tune the settings as needed.

8 Troubleshooting

Problem

Possible causes

Connected load
does not switch
ON.

Check the 

LUX

 setting, it should correspond to ambient light levels. E.g., if it

is set too high the sensor will not trigger in the dark.

Check the power supply is functioning correctly.

Check if the connected device (e.g., lamp) is functioning correctly.

Movements within the detection area are too rapid and are filtered out by the
electronic system to prevent switching errors.

The switch is in the 

OFF

 position. Set it to 

ON

 or 

AUTO

.

Motion detection is
not functioning cor-
rectly

The ambient temperature is too high.

There are obstructions preventing the sensor from detecting heat sources
(e.g., glass).

Check that if there are induction sources within detection area.

Observe the correct installation height. See section “Technical data” for fur-
ther information.

The connected load
is always ON.

Constant movements are occurring within the detection area.

New movement is detected before the previous switch-ON time has elapsed.
Try setting a shorter time interval.

The switch is in the 

ON

 position. Set it to 

OFF

 or 

AUTO

.

9 Cleaning and care

Important:

The product is generally maintenance-free. Any repair or maintenance work must be carried
out by a specialist.

Clean the product with a dry, fibre-free cloth.

NOTICE! Do not use aggressive cleaning agents, rubbing alcohol or other chemical solutions as
they can cause damage to the housing and malfunctioning.

10 Disposal

Electronic devices are recyclable waste and must not be disposed of in the household waste.
At the end of its service life, dispose of the product in accordance with applicable regulatory
guidelines.

You thus fulfill your statutory obligations and contribute to the protection of the environment.

11 Technical data

Operating voltage  .................................. 220 – 240 V/AC 50/60 Hz

Rated load .............................................. max. 500 W resistive (e.g. incandescent lamp)

max. 200 W inductive (e.g. energy-saving lamp or LED)

Power consumption  ............................... 0.42 W (static)

0.15 W (active)

Switch contact......................................... triac

PIR sensor activation ............................. <3 – 2000 lux (adjustable)

PIR sensor time delay (adjustable)......... 10 sec ±3 s to 7min± 2 min

PIR sensor detection range  ................... max. 10 m (<24 ºC)

PIR sensor detection angle .................... Horizontal: 190°, Vertical: 120°

PIR sensor installation height  ................ 1 – 1.8 m

PIR sensor detection speed.................... 0.6 - 1.5 m/s

Protection class ...................................... II

Ingress protection  .................................. IP65

Operating temperature ........................... -5 to +30 °C

Storage temperature .............................. -20 to +40 °C

Dimensions (L x W x H) (approx.) .......... 86 x 86 x 64 mm

Weight (approx.)  .................................... 126 g

25,8 mm

53,5 mm

86,0 mm

53,5 mm

86,0 mm

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).

All rights including translation reserved. Reproduction by any method (e.g. photocopying, microfilming or the capture in
electronic data processing systems) requires prior written approval from the editor. Reprinting, also in part, is prohibited.
This publication reflects the technical status at the time of printing.

Copyright by Conrad Electronic SE.

*2377682_V1_0721_dh_mh_en

Summary of Contents for SY-4755364

Page 1: ... Produkt außer Betrieb und schützen Sie es vor unbeabsichtigter Verwendung Der sichere Betrieb ist nicht mehr gewährleistet wenn das Produkt sichtbare Beschädigungen aufweist nicht mehr ordnungsgemäß funktioniert über einen längeren Zeitraum unter ungünstigen Umgebungsbedingungen gelagert wurde oder erheblichen Transportbelastungen ausgesetzt wurde Gehen Sie stets vorsichtig mit dem Produkt um Stö...

Page 2: ...lers LUX und stellen Sie sicher dass sie Ihrem gewünschten Wert für die Umgebungslichtstärke entspricht Ist die Einstellung z B zu hoch löst der Sensor bei Dunkelheit nicht aus Problem Möglich Ursachen Vergewissern Sie sich dass die Netzstromversorgung ordnungsgemäß funk tioniert Überprüfen Sie ob der angeschlossene Verbraucher z B die Leuchte eine Betriebsstörung aufweist Die Bewegungen innerhalb...

Page 3: ...his information product contact our technical support service or other technical personnel 5 2 Handling If it is no longer possible to operate the product safely take it out of operation and protect it from any accidental use Safe operation can no longer be guaranteed if the product is visibly damaged is no longer working properly has been stored for extended periods in poor ambient conditions or ...

Page 4: ...ection area are too rapid and are filtered out by the electronic system to prevent switching errors The switch is in the OFF position Set it to ON or AUTO Motion detection is not functioning cor rectly The ambient temperature is too high There are obstructions preventing the sensor from detecting heat sources e g glass Check that if there are induction sources within detection area Observe the cor...

Page 5: ...la réponse ne figure pas dans ce mode d emploi contactez notre service d assistance technique ou un autre technicien spécialisé 5 2 Manipulation Si une utilisation du produit en toute sécurité n est plus possible arrêtez de l utiliser et protégez le de toute utilisation accidentelle Un fonctionnement sûr ne peut plus être garanti si le produit est visiblement endommagé ne fonctionne plus correctem...

Page 6: ...rité Vérifiez que l alimentation électrique fonctionne correctement Vérifiez si l appareil connecté p ex la lampe fonctionne correctement Les mouvements dans la zone de détection sont trop rapides et sont filtrés par le système électronique pour éviter les erreurs de commutation Le commutateur est réglé sur OFF Réglez le sur ON ou PIR La détection de mouvement ne fonctionne pas cor rectement La te...

Page 7: ...lantendienst of ander technisch personeel 5 2 Omgang Als het product niet langer veilig gebruikt kan worden stel het dan buiten bedrijf en zorg ervoor dat niemand het per ongeluk kan gebruiken Veilig gebruik kan niet langer worden gegarandeerd als het product zichtbaar is beschadigd niet meer naar behoren werkt gedurende een langere periode onder slechte omstandigheden is opgeslagen of onderhevig ...

Page 8: ...ewegingen binnen het detectiegebied zijn te snel en worden door het elek tronische systeem uitgefilterd om schakelfouten te voorkomen De schakelaar staat in de stand OFF Stel het in op ON of PIR De bewegingsde tectie werkt niet correct De omgevingstemperatuur is te hoog Er zijn obstakels waardoor de sensor geen warmtebronnen kan detecteren bijv glas Controleer of er inductiebronnen binnen het dete...

Reviews: