Connection diagram (e.g. lighting fixture):
1
Connecting a device with protection class II
Remove the two covers from the built-in switch. If they are
fastened with screws, unscrew them first.
For devices with protection class II, a two-core mains supply
cable without a protective conductor must be used (two-pole
cable).
If you want to integrate the built-in switch into the connection
cable of the device, cut the connection cable at the desired
location. However, make sure that the cable is still long
enough for it to be connected properly.
Remove the outer insulation of the mains supply cable and
the cable to the device (e.g. a lighting fixture) at a length of
about 10.5 mm. Strip each of the two wires to a length of
about 6 mm.
/