Sygonix 1574789 Operating Instructions Manual Download Page 4

Operation

  Read and follow the chapter “Safety information” carefully.

•  For operation, unwind the mains cable of the power strip completely and without loops.
•  Mount the product in a suitable location. Lay the cable such that nobody will trip over it. Use 

suitable padding to protect valuable surfaces against scratches.

•  Insert the plug into a properly earthed mains socket (wall socket).
•  Connect up to three consumers to the sockets on the power strip.
•  If the power strip has an on/off switch (see ‘Technical data'), you can use it to switch all 

consumers on or off. The indicator light in the on/off switch illuminates when switched on.

Socket Strip Item No. 1574789, 1732743

This power strip has surge protection. The surge protection is ready when the red warning 

light shines.
If the red warning light does not shine, the surge protection has tripped. In this case, the socket 

strip may still be used, but surge protection is no longer provided.
The green control light indicates that the protective conductor is available (control light is 

activated). 

  If the socket strip is connected to the mains voltage (and the mains voltage is availa-

ble), but the green control light does not shine, something is wrong with the voltage/

power supply. Unplug the mains plug of the socket strip from the mains socket. Do 

not connect any device to the mains socket, but have it checked by an expert.

Care and cleaning

•  This product does not require maintenance. This product does not contain any components 

that require maintenance. Never attempt to open or disassemble it. Repair or maintenance 

work must be carried out by a technician or a specialist repair centre.

•  Disconnect the product from the power supply before cleaning. 

  Never use aggressive detergents, rubbing alcohol or other chemical solutions, as 

these may damage the housing or prevent the product from functioning properly.

•  Use a dry, lint-free cloth to clean the product.

Disposal

  Electronic devices are recyclable waste and must not be placed in household waste. 

At the end of its service life, dispose of the product in accordance with applicable 

regulatory guidelines.

You thus fulfil your statutory obligations and contribute to environmental protection.

Specifications

 

See table to the right.

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). 

All rights including translation reserved. Reproduction by any method (e.g. photocopying, microfilming or capturing in elec

-

tronic data processing systems) requires prior written approval from the publisher. Reprinting, also in part, is prohibited. 

This publication reflects the technical status at the time of printing.

Copyright 2021 by Conrad Electronic SE. *2446231_v2_1021_02_DS_m_4L_(1)

Item No.

Connection data

Total connection  load

Earthed mains  sockets

Sockets with enhanced  contact protection

On/off switch

Overvoltage protection

Length of  cable

Cable type

Dimensions

 

(L

 x W x H)

Ambient temperature

Ambient humidity 

 

(relative, non-condensing)

1574789

250 V/AC, 50 Hz, 16 

A

3680 W (max.)

6

yes

yes (bipolar)

yes (leakage current 9 kA)

1.4 m

H05VV

-F 3G1.5 mm²

365 x 48 x 52 mm

-10 °C to +50 °C

10% to 90%

1732743

250 V/AC, 50 Hz, 16 

A

3680 W (max.)

5

yes

yes (bipolar)

yes (leakage current 9 kA)

1.4 m

H05VV

-F 3G1.5 mm²

320 x 47 x 52 mm

-10 °C to +50 °C

10% to 90%

2446231

230 V/AC, 50 Hz, 16 

A

3680 W max.

3

yes

no

no

1.4 m

H05VV

-F 3G1.5 mm²

180 x 54 x 44 mm 

-10 °C to +50 °C

10 % to 90 %

2445488

230 V/AC, 50 Hz, 16 

A

3680 W max.

3

yes

no

no

1.4 m

H05VV

-F 3G1.5 mm²

180 x 54 x 44 mm 

-10 °C to +50 °C

10 % to 90 %

2445489

230 V/AC, 50 Hz, 16 

A

3680 W max.

3

yes

no

no

3m

H05VV

-F 3G1.5 mm²

180 x 54 x 44 mm 

-10 °C to +50 °C

10 % to 90 %

2445490

230 V/AC, 50 Hz, 16 

A

3680 W max.

3

yes

no

no

3m

H05VV

-F 3G1.5 mm²

180 x 54 x 44 mm 

-10 °C to +50 °C

10 % to 90 %

2445491

230 V/AC, 50 Hz, 16 

A

3680 W max.

3

yes

no

no

4.8 m

H05VV

-F 3G1.5 mm²

180 x 54 x 44 mm 

-10 °C to +50 °C

10 % to 90 %

2445492

230 V/AC, 50 Hz, 16 

A

3680 W max.

3

yes

yes

no

1.4 m

H05VV

-F 3G1.5 mm²

200 x 54 x 44 mm 

-10 °C to +50 °C

10 % to 90 %

2445493

230 V/AC, 50 Hz, 16 

A

3680 W max.

3

yes

yes

no

1.4 m

H05VV

-F 3G1.5 mm²

200 x 54 x 44 mm 

-10 °C to +50 °C

10 % to 90 %

2445494

230 V/AC, 50 Hz, 16 

A

3680 W max.

3

yes

yes

no

2.8 m

H05VV

-F 3G1.5 mm²

200 x 54 x 44 mm 

-10 °C to +50 °C

10 % to 90 %

2445495

230 V/AC, 50 Hz, 16 

A

3680 W max.

3

yes

yes

no

2.8 m

H05VV

-F 3G1.5 mm²

200 x 54 x 44 mm 

-10 °C to +50 °C

10 % to 90 %

2445496

230 V/AC, 50 Hz, 16 

A

3680 W max.

6

yes

no

no

1.4 m

H05VV

-F 3G1.5 mm²

310 x 54 x 44 mm 

-10 °C to +50 °C

10 % to 90 %

2445497

230 V/AC, 50 Hz, 16 

A

3680 W max.

6

yes

no

no

1.4 m

H05VV

-F 3G1.5 mm²

310 x 54 x 44 mm 

-10 °C to +50 °C

10 % to 90 %

2445498

230 V/AC, 50 Hz, 16 

A

3680 W max.

6

yes

no

no

2.8 m

H05VV

-F 3G1.5 mm²

310 x 54 x 44 mm 

-10 °C to +50 °C

10 % to 90 %

2445499

230 V/AC, 50 Hz, 16 

A

3680 W max.

6

yes

no

no

2.8 m

H05VV

-F 3G1.5 mm²

310 x 54 x 44 mm 

-10 °C to +50 °C

10 % to 90 %

2445500

230 V/AC, 50 Hz, 16 

A

3680 W max.

6

yes

no

no

4.8 m

H05VV

-F 3G1.5 mm²

310 x 54 x 44 mm 

-10 °C to +50 °C

10 % to 90 %

2445501

230 V/AC, 50 Hz, 16 

A

3680 W max.

6

yes

yes

no

1.4 m

H05VV

-F 3G1.5 mm²

330 x 54 x 44 mm 

-10 °C to +50 °C

10 % to 90 %

2445502

230 V/AC, 50 Hz, 16 

A

3680 W max.

6

yes

yes

no

1.4 m

H05VV

-F 3G1.5 mm²

330 x 54 x 44 mm 

-10 °C to +50 °C

10 % to 90 %

2445503

230 V/AC, 50 Hz, 16 

A

3680 W max.

6

yes

yes

no

2.8 m

H05VV

-F 3G1.5 mm²

330 x 54 x 44 mm 

-10 °C to +50 °C

10 % to 90 %

2445504

230 V/AC, 50 Hz, 16 

A

3680 W max.

6

yes

yes

no

2.8 m

H05VV

-F 3G1.5 mm²

330 x 54 x 44 mm 

-10 °C to +50 °C

10 % to 90 %

Summary of Contents for 1574789

Page 1: ...st ndig ab Das Netzkabel darf nicht gequetscht oder durch scharfe Kanten besch digt werden Stellen Sie keine Gegenst nde auf das Netzkabel treten Sie nicht darauf Verlegen Sie das Netzkabel so dass ni...

Page 2: ...ne Publikation der Conrad Electronic SE Klaus Conrad Str 1 D 92240 Hirschau www conrad com Alle Rechte einschlie lich bersetzung vorbehalten Reproduktionen jeder Art z B Fotokopie Mikroverfilmung oder...

Page 3: ...l socket The power strip is only fully isolated from the mains when the plug has been unplugged Only use the product in temperate climates It is not suitable for use in tropical climates Do not connec...

Page 4: ...hibited This publication reflects the technical status at the time of printing Copyright 2021 by Conrad Electronic SE 2446231_v2_1021_02_DS_m_4L_ 1 Item No Connection data Total connection load Earthe...

Page 5: ...drukt of door scherpe objecten beschadigd wordt Zet geen voorwerpen op het netsnoer en ga er nooit op staan Leg het netsnoer zo dat niemand erover kan struikelen en dat de stekker eenvoudig toegankeli...

Page 6: ...Hirschau www conrad com Alle rechten voorbehouden met inbegrip van vertalingen Reproducties van welke aard dan ook bijvoorbeeld fotokopie microverfilming of de registratie in elektronische gegevensve...

Page 7: ...icato o danneggiato da spigoli appuntiti Non porre mai oggetti sul cavo di alimentazione Posizionare il cavo di alimentazione in modo che nessuno possa inciamparvi e che la spina sia facilmente access...

Page 8: ...irschau www conrad com Tutti i diritti compresa la traduzione sono riservati vietata la riproduzione di qualsivoglia genere quali fotocopie micro film o memorizzazione in attrezzature per l elaborazio...

Reviews: