3.3 Files Backup Application
Please consult the help of application software for the backup application
installation and operation.
3.4 Replacing Hard Drives
When one drive fails, the HDD LED will display below state:
If HDD1
Fails
: LED1 off
If HDD2
Fails
: LED2 off
If one drive fails and the RAID mode is set to RAID0 or JBOD,the data will
be lost and the system can not be accessed again until the drive have been
replace.
1. Check the HDD LED state and replace the faulty drive.The power
must turn off when replacing the driver.
2. For RAID 1, the RAID array will be rebuilt automatically.During this
process, the HDD LED will flash (HDD R/W). Rebuilding the RAID
array will take several hours,depending on the drive capacity.If RAID
rebuilding is OK, the HDD LED will keep light normally.If the capacity
of the new drive is less than the previous drive, the HDD LED will
display as above state.The rebuild process can not be completed.