Rear Panel 

 

Item 

Description 

S/PDIF OUT 

Coaxial S/PDIF digital de-embedded audio outputs 

IN1 to IN4 

HDMI video input connectors 

OUT1 to OUT4 

HDMI video output connectors 

IR IN 

Input from IR EYE sensor 

RS232 

RS232 control port 

Service 

For system upgrade & engineering diagnostics only 

LAN CTL 

LAN control or access to the built-in web interface 

5V DC 

5V DC input 

System Connection 

Usage Precautions 

This HDMI matrix switcher should be installed in a clean environment that has adequate 
ventilation, temperature and humidity control. 
All switches, plugs, sockets and power cables must be insulated and safety approved. 
All devices should be connected before powering on. 

Connection Procedure 

 

Connect the HDMI source devices to the HDMI IN connectors of the switcher. 

 

Connect display devices to the HDMI output connectors as required. 

 

Connect the 5V DC PSU provided with your switcher to the DC input connector. 

Using the MS44-18G 

Manual Selection 

To change the displayed image for any output, press the appropriate 

Select

 button on 

the front panel, to select the required input. The numbered LED on the front panel will 
light to indicate the current input selection for that output. 

IR Remote Control 

The IR remote control provided with the switcher may also be used to select the 
images, by first pressing an output number or the ALL button in the 

Output

 group (1-4), 

and then an input number in the 

Input

 group (1-4). 

The 

PTP

 button on the IR remote will make the following selections: 1 

 1, 2 

 2,      

 3 and 4 

 4. 

Press 

X

 button to cancel operation and 

power

 button for standby mode. All other 

buttons are to be ignored. 

Summary of Contents for MS44-18G

Page 1: ...SY Electronics Ltd 7 Worrall Street Salford Manchester M5 4TH UK Tel 44 0 161 868 3450 Fax 44 0 161 868 3459 Web sy uk User Manual MS44 18G 4x4 HDMI2 0 Matrix 4K2K 60Hz YCbCr 4 4 4...

Page 2: ...tion distribution conference room presentation school and corporate training environments Features 4x HDMI 2 0 Inputs 4x HDMI 2 0 outputs 4x de embedded S PDIF audio outputs Supports 4K2K 60Hz YUV4 4...

Page 3: ...t the HDMI source devices to the HDMI IN connectors of the switcher Connect display devices to the HDMI output connectors as required Connect the 5V DC PSU provided with your switcher to the DC input...

Page 4: ...mands Connecting the MS44 18G RS232 and IP Commands All RS232 commands are sent with the following settings 115200 baud 8 bits no parity and 1 stop bit All commands are stated in ASCII notation and mu...

Page 5: ...scription W 50 Reboot Mimics repowering the matrix switcher W 51 Restore Factory Settings Removes all previously programmed settings EDID Settings Command Description W XX AA BB XX is the Input Number...

Page 6: ...binary bits in the above table will need to be converted to their hexadecimal form as sent as two ASCII characters for example To set the EDID for input 1 to 4K2K 60 YC444 HDR 48 bit colour 7 1ch audi...

Page 7: ...me panel will allow the user to set a unique name for the matrix switcher that can aid in device identification when installed in a network system Port Set Panel The Port Set panel allows for video se...

Page 8: ...g any changes click the relevant Apply button to store them in the matrix switcher The Read button for each input group reads the data from the current EDID mode of the respective input on the matrix...

Page 9: ...that the MAC address is fixed and cannot be changed Net Config Panel The Net Config panel provide the following features Determine how many SY MS44 18G matrix switchers are on the local network and th...

Page 10: ...he Search Device button to obtain a list of all SY MS44 18G units on the local network Use the Set Device Number list to choose the desired matrix switcher Click the Connect button in the Host Device...

Page 11: ...tatus This will be required whenever the IP settings are changed Turn the matrix switcher ON or OFF o The OFF state is a standby mode that will only respond to the power ON command While in this mode...

Page 12: ...IP address in the address bar of a web browser If the IP settings are not known then use the RS232 control software to determine the current IP settings of the SY MS44 18G as described for the IP Con...

Page 13: ...60Hz YCbCr 420 shown as YC420 4K2K 60Hz YCbCr 444 shown as YC444 Copy From TV1 Copy From TV2 Copy From TV3 Copy From TV4 Note that the last four options Copy From TV1 to Copy From TV4 do not allow an...

Page 14: ...gs will only take effect after clicking on the Apply button Changes to the IP settings are only allowed when the DHCP box is not checked Note that the MAC address cannot be changed at all The Device N...

Page 15: ...ats including Dolby D TrueHD DTS HD Master Audio PCM Channel count from 2 8 2 0 to 7 1 Sample rates 32 kHz 44 1 kHz 48 kHz 88 2 kHz 96 kHz 176 4 kHz and 192 kHz De embedded Audio Out S PDIF digital au...

Page 16: ...quids or harmful chemicals to come into contact with this product After Sales Service 1 Should you experience any problems while using this product firstly refer to the Troubleshooting section in this...

Reviews: