Troubleshoot   

Please use the form below to check the infrared camera when it 

has any trouble. Disconnect the power and contract our technical 

support department if the problem cannot be fixed. 

Malfunction 

Reason and solution 

Video tracker cannot 
start/Power light is not on 

1.

 

Check whether the power is connected. 

2.

 

Check whether the voltage is lower than required 

which should be 12V. 

No image display 

1.

 

Check whether the serial port is open(not serial port 1) 

2.

 

Check whether the baud rate setting of the operation 

software is correct. 
3.

 

Check whether the video output format of the 

displayer is 1080I/1080P. 

The serial command does not 
respond 

1.

 

Check whether the serial port is open (not serial port 1 

open) Check whether the verification mode is correct. 

No tracking box 

1. The target is too close or not obvious, reselect target. 

 

Pin Definition 

 

 

 

 

 
 
 

Pin # 

Pin Title 

Function 

POWER IN 

+12V power input 

POWER IN 

+12V power output 

GND 

GND 

GND 

GND 

RXD 

Serial port receive 

TXD 

Serial port send 