I-PLUG
IPST8 V.2 aug 2017
I-Plug pdf
Page
2
of
8
How does it work?
How to START it?
When you are ready to use
I-PLUG
Logger
, press the START button till the 4 LED’s
flash – release only when the GREEN LED is active.
The GREEN LED will remain active during the first
2 minutes
of recording.
After the first 2 minutes of recording, press briefly any of the two buttons to get the device
status (see meanings below)
Start Delay
As a factory setting, I-PLUG
will start recording 30 min after pressing the START button.
How to STOP it?
I-PLUG
is programmed with a typical trip duration, and will keep recording until the end
of this trip duration
There are two different ways to STOP the device before the end of the trip duration:
-
Press the
STOP
button during 6 seconds till the 4 LED’s flash – release only when the
RED LED is active and fixed.
-
Connect
the device on the USB port of the computer
Once stopped, pressing any button will briefly activate The RED LED as an indication that
the device has finished recording.
Configuring I-PLUG
I-PLUG
data logger comes already configured to standard formats according to your
purchase.
The standard trip duration is
90 days
.
Nevertheless if you wish to change the configuration like
•
Changing the recording time
•
Temperature scale (C°/F°)
•
Adding alarms
•
Changing start delay
•
Entering text in the device memory
You just need to plug it in a computer before being activated and use the
iPlug Manager
s
oftware. Get the
iPlug Manager
software in the “Downloads” section of our website
www.switrace.com
.