How does it work? 

How to START it? 

When you are ready to use 

I-PLUG 

pdf 

Logger

, press the START button till the 4 LED’s 

flash – release only when the GREEN LED is active.  
The GREEN LED will remain active during the first 

2 minutes

 of recording. 

After the first 2 minutes of recording, press briefly any of the two buttons to get the device 
status (see meanings below) 

Start Delay 

As a factory setting, I-PLUG 

pdf 

will start recording 30 min after pressing the START button. 

How to STOP it? 

I-PLUG 

pdf

 is programmed with a typical trip duration, and will keep recording until the end 

of this trip duration  
There are two different ways to STOP the device before the end of the trip duration: 

-

 

Press the 

STOP 

button during 6 seconds till the 4 LED’s flash – release only when the 

RED LED is active and fixed. 

-

 

Connect

 the device on the USB port of the computer 

Once stopped, pressing any button will briefly activate The RED LED as an indication that 
the device has finished recording. 

Configuring I-PLUG 

pdf

 

I-PLUG 

pdf

 data logger comes already configured to standard formats according to your 

purchase.  
The standard trip duration is 

90 days

Nevertheless if you wish to change the configuration like  

 

Changing the recording time 

 

Temperature scale (C°/F°) 

 

Adding alarms 

 

Changing start delay 

 

Entering text in the device memory  

You just need to plug it in a computer before being activated and use the 

iPlug Manager 

s

oftware. Get the 

iPlug Manager 

software in the “Downloads” section of our website 

www.switrace.com

.  

Summary of Contents for I-PLUG pdf

Page 1: ...mensions 7 5 cm x 4 cm x 0 5 cm Temperature measurement range 40 to 65 Degrees Celsius Temperature resolution 0 01 C Data storage capacity 8000 Measurements Log cycle 5 days to 90 days No software nee...

Page 2: ...t ways to STOP the device before the end of the trip duration Press the STOP button during 6 seconds till the 4 LED s flash release only when the RED LED is active and fixed Connect the device on the...

Page 3: ...art button is active In a RUNNING state when a button is pressed Blinking Green This confirms that the device is already started NOTE there is a fixed green LED during the first 2 minutes of recording...

Page 4: ...ped As soon as the I PLUG pdf is connected to the PC via the USB port the computer will automatically detect the device The first time I PLUG pdf is plugged in it will trigger the creation of the PDF...

Page 5: ...software iPlug Manager in the Download section of www switrace com You do not need to register to download the software Modify settings of I PLUG pdf iPlug Manager allows you to modify all the pre pro...

Page 6: ...I PLUG pdf IPST8 V 2 aug 2017 I Plug pdf Page 6 of 8 Temperature information will be displayed in RED while temperature readings will appear on the left side of the screen...

Page 7: ...topped and plugged into the PC with iPlug Manager you could send the data recorded to the web and allow yourself to export data in excel files zoom on the graph and many other features Just press the...

Page 8: ...y settings of I PLUG single use iPlug MANAGER allows you to modify all the pre programmed setting and choose your own Just modify all the parameters you need then press the Save settings button Pic 1...

Reviews: