4. TSL Connection
4.1 Protocol version
S-9104+ supports TSL3.1 and TSL4.0 protocol
4.2 Terminal definition
S-9104+ supports RS485 socket for the upstream equipments using TSL protocol, and terminal
description is as follows:
* 38400 baud rate, no parity bit, 1 stop bit and 8 data bits
4.3 TSL protocol address setting
(1) Press the above mentioned six buttons from right to left in order (“TIME-CODE”
“MARKER/SD-RATIO”
“CH-2”
“CH-1”
“WINDOW1”
“WINDOW1”) to enter the address setting menu.
(2) The address setting menu is as above, revolve “OK” to choose from 0~9, and press “OK” to finish every
digit of the TSL_Addr. (the address range is 0-126). After setting, press “LOGO-SET” to save the address.
Terminal
1
2
3
4
5
6
7
8
9
Description
485B 485A