SWIT Electronics PC-P460S User Manual Download Page 2

Charging and Display Function

Specifications

1. Standby

Charging status indicator

0%~80% Red light always on
81%~99% Green light flash
100% Green light always on
Error

Red light flash

LCD Screen

2. Charging

 After mounting the battery, the charger prepares to charge.

 Show the capacity and cycle times for 5s,then enter in charging interface

.

 Show the percentage of battery capacity, battery voltage and the charging current. 

 Charging complete.

 Battery abnormal situation handling interface, waiting for about 30s to exit this interface.

3. Relationship between charging current and battery temperature of fast charging battery: 

Battery temperature

<45

≥45

Charging current

6A

3A

Battery regain 6A fast charge after battery 

temperature is under 40

①  

When the battery get over-heat protection, charger can recognize the temperature of battery, battery will be recharged after       

       the temperature is under 45

4. Error

Code of Error

E01

E02

E03

E04

E05

Battery initialization failed

Communication failed

Charger over-heat protection

Charger fault

Self-check fault

Please check the battery status and try to replug.

Please replug the battery.

Please check if the fan is working normally, If so, move the charger to a cold place.

Please replug the battery.

Please restart the charger.

Model

Mounting model

Input voltage

Input power

Output voltage/current

Operating temperature

Operating humidity

Dimension  

Net weight

PC-P460S

V-Mount   

100

240VA,50/60Hz

450W(Max)

16.8V, 3A /6A×4ch

0

~40

10%RH~90%RH

330×153×162mm

About 2.43kg

PC-P460A

Gold-Mount

PC-P460B

B-Mount

33.6V, 3A×4ch

330×135.6×162mm

330×140×162mm

①                                      ②                                     ③                                       ④                                        ⑤