Charging and Display Function
Specifications
1. Standby
Charging status indicator
:
0%~80% Red light always on
81%~99% Green light flash
100% Green light always on
Error
:
Red light flash
LCD Screen
:
2. Charging
①
After mounting the battery, the charger prepares to charge.
②
Show the capacity and cycle times for 5s,then enter in charging interface
③
.
③
Show the percentage of battery capacity, battery voltage and the charging current.
④
Charging complete.
⑤
Battery abnormal situation handling interface, waiting for about 30s to exit this interface.
3. Relationship between charging current and battery temperature of fast charging battery:
Battery temperature
<45
℃
≥45
℃
Charging current
6A
3A
,
Battery regain 6A fast charge after battery
temperature is under 40
℃
①
When the battery get over-heat protection, charger can recognize the temperature of battery, battery will be recharged after
the temperature is under 45
℃
.
4. Error
Code of Error
:
E01
E02
E03
E04
E05
Battery initialization failed
Communication failed
Charger over-heat protection
Charger fault
Self-check fault
Please check the battery status and try to replug.
Please replug the battery.
Please check if the fan is working normally, If so, move the charger to a cold place.
Please replug the battery.
Please restart the charger.
Model
Mounting model
Input voltage
Input power
Output voltage/current
Operating temperature
Operating humidity
Dimension
Net weight
PC-P460S
V-Mount
100
~
240VA,50/60Hz
450W(Max)
16.8V, 3A /6A×4ch
0
℃
~40
℃
10%RH~90%RH
330×153×162mm
About 2.43kg
PC-P460A
Gold-Mount
PC-P460B
B-Mount
33.6V, 3A×4ch
330×135.6×162mm
330×140×162mm
① ② ③ ④ ⑤