7
A blue
Neutrik powerCON NAC3FCA
cable mount connector must be used to supply power at the XND-8
’s
power input
socket.
Warning! For protection against dangerous electrical shocks, the device must be grounded (earthed). The
local AC power source must be supplied with both overload and ground-fault (earth fault) protection.
Important! Only attach or remove a Neutrik powerCON connector while it is connected to the mains to
apply or cut power in an emergency, as by doing so may cause arcing at the terminals that will damage
the connectors.
Power Outlet
Warning! The total current load of all devices connected to the AC mains power outlet of the XND-8 must
not exceed 19.8 amperes.
• A p
ower cable that meets the requirements specified in the safety instructions section of this manual must be used
to connect the XND-8 to AC mains power and to connect other devices to the power outlet.
• A light
-grey Neutrik powerCON NAC3FCB cable-mount connector must be used to draw AC mains power from the
XND-8
’s power outlet
.
• No matter what the AC
mains power voltage is, the current drawn by all the devices that draw AC mains power from
the power outlet of an XND-8 must not exceed a total of 19.8 amperes.
DMX Connections
Depending on the version, the XND-8 is equipped with 5-pin or 3-pin XLR connectors or with Neutrik etherCON RJ45
connectors.
XLR Connectors
RJ45 Connectors
Each output port is individually optically isolated.
Pin
Connection
1
Com
2
Data -
3
Data +
4
Not connected
5
Not connected
Pin
Connection
1
Data +
2
Data -
3
Not connected
4
Not connected
5
Not connected
6
Not connected
7
Com
8
Com
Shield
Earth