9
• A light
-grey Neutrik powerCON NAC3FCB cable-mount connector must be used to draw AC mains power from the
XND-4
’s power outlet
.
• No
matter what the AC mains power voltage is, the current drawn by all the devices that draw AC mains power from
the power outlet of an XND-4 must not exceed a total of 19.8 amperes.
DMX Connections
Depending on the version, the XND-4 is equipped with 5-pin or 3-pin XLR connectors, with RJ45 connectors or 3-pole
box header connectors.
XLR Connectors
RJ45 Connectors
Box Header Connectors
Each port is individually optically isolated.
On the XND-4D, a box header and a RJ45 connector is available for each DMX port. Please note that only one of the
two sockets should be used at a time. Also, there is no isolation between the sockets that belong to the same DMX
port.
Pin
Connection
1
Com
2
Data -
3
Data +
4
Not connected
5
Not connected
Pin
Connection
1
Data +
2
Data -
3
Not connected
4
Not connected
5
Not connected
6
Not connected
7
Com
8
Com
Shield
Earth
Pin
Connection
1
Data +
2
Data -
3
Com