Connecting the pump to the circuit:
The pump’s inlet and outlet are 3/8” in outside diameter. Use with 3/8” ID (1/2” OD) tubing, or 10mm ID (12mm OD) for Europe.
4.
Performance & Specifications
Nominal voltage
12 V DC
Operating voltage range
8 to 13.2 VDC
Minimum starting voltage
9 V DC
Nominal power (@ 12 V)
18 W
Nominal current@ 12v
1.46 amps
Nominal discharge @ 12v
~120 GPH (454 LPH)
Nominal head @ 12 v
20.2 ft (6.1mm)
Connection size
3/8” barbs (10mm)
Maximum pressure
22 PSI (1.5 BAR)
Temperature range
Up to 140°F (60°C)
Electrical connector
Molex 4 pin
Weight
7.3 oz (207 gr.)
Our noise measurement
(non lab environment)
30 ~ 32 dBA in a quiet
room @ 2’
Motor type
Electronically
commutated, brushless
DC, spherical motor
MTBF (Mean Time between
failures)
50,000 hours
5.
Permanent installation to the chassis, and exploded view
Drill two 0.312” (8mm) holes into panel, 2.52” (64mm) apart. Snap grommet into each
hole. Tighten the provided screws until the pump neoprene pad is slightly and evenly
compressed by approximately 1/8” (2~3mm) or less.
DISCLAIMER:
Swiftech assumes no liability whatsoever, expressed or implied, for the use of this product, and more specifically for any, and
all damages caused by the use of this product to any other devices in a personal computer, whether due to product failure, leak, electrical
shorts, and or electro-magnetic emissions.
WARRANTY:
This product is guaranteed for a period of
24 months
from date of purchase for defects in material, and workmanship.
Guarantee consists of replacing defective parts with new or reconditioned parts. Guarantee is considered void in case of
improper use
(*)(**)(***)
, handling or negligence on the part of user.
Original invoice showing date and place of purchase is required for exercise of the
warranty.
(*) WARNING: DO NOT ATTEMPT TO RUN THIS PUMP DRY. THIS WILL CAUSE IMMEDIATE AND PERMANENT DAMAGE TO THE PUMP. (**)
EXCESSIVE WEAR DUE TO INNAPROPRIATE FLUIDS. (***) EXCESSIVE RESTRICTION TO THE PUMP’S INLET