Operation Instruction of AQUAFLOW Series Solar Pumping Inverter Installation and Wiring
22
11K
AQUAFLOW
13K
28
3HP 380V
6
6
10
10
10
10
AQUAFLOW
15K
30
3HP 380V
6
6
10
10
16
16
AQUAFLOW
18K5
39
3HP 380V
6
10
10
16
16
25
AQUAFLOW
22K
45
3HP 380V
10
16
16
25
25
Units: mm
2
Notice: the environment temperature of the above recommended wire dimension is
≤
50°C.
Notice: large-power wall-mounted model uses multiple-channel DC input. The dimension
of DC wire of each channel shall be selected according to the above table.
2.5 Assemble DC Connector
2.5.1 Strip the cable 6-8mm,then connect the bare wire core into core tube of connector .
Figure 2-22 DC Line connects with wiring board
2.5.2 Crimp contact barrel by using a hex crimping die.Put the contact barrel with striped cable in
the corresponding crimping notch and crimp the contact.Insert the core tube into slot of connection
until hear the voice indicating in place.