background image

WISE 

Parasol Zenith b

6

Swegon reserves the right to alter specifications.                           20/06/2019

 

Accessory - Centring when mounting in concealed T-bars.

90°

Recommended number of plates per product.

Length of the 

unit 

600

4

1200 

6

1800

6-8

Summary of Contents for WISE Parasol Zenith 600

Page 1: ...4 Accessory Quick bracket 5 Accessory Centring when mounting in concealed T bars 6 Accessory Fold out coil 7 Water 8 Air 9 Commissioning 10 ADC 10 Connections 11 LED Explanation 11 Use 12 Trouble sho...

Page 2: ...not permissible to insert foreign objects into the product s contactor connections or ventilation openings risk for short circuiting 24 V isolation transformer to be connected should comply with the p...

Page 3: ...20 250 368 1185 1106 1342 667 182 125 160 506 585 87 102 220 250 368 1185 1106 Dimensions refer to WISE Parasol Zenith 600 with air connection 125 160 When WISE SMB is installed in the face plate the...

Page 4: ...acement of the bracket on delivery Length of the unit c c mm X c c mm Y 600 330 10 508 10 1200 930 10 508 10 1800 1530 10 508 10 Alternative placement of the suspension bracket A A1 A2 Length of the u...

Page 5: ...h 600 and 1200 Installation with quick bracket accessory A Installation with one centred threaded rod per quick bracket M8 M8 c c measurement Air connection side Short side Long side Length of the uni...

Page 6: ...l Zenith b 6 Swegon reserves the right to alter specifications 20 06 2019 Accessory Centring when mounting in concealed T bars 90 Recommended number of plates per product Length of the unit 600 4 1200...

Page 7: ...to alter specifications WISE Parasol Zenith b The accessory fold out coil requires flexible hose connections on the water side Accessory Fold out coil For easy access and cleaning stringent demands ar...

Page 8: ...N15 male thread Supply pipe Plain pipe 12 x 1 0 mm A Cooling only 1800 Actuator and valve Return DN20 external threads Supply pipe Plain pipe 15 x 1 0 mm B Cooling Heating 1800 Actuator and valve Retu...

Page 9: ...crew two screws each from the spigot and cover 2 Change the location of the spigot and cover 3 Screw the spigot and cover in position each with two screws on the new side A 2 1 1 1 4 4 2 600 1200 1800...

Page 10: ...guarantees the highest level of indoor climate with minimum energy consumption This means that when the installation and pairing of the system is completed no further trimming is required except for a...

Page 11: ...sol Zenith connection LED Explanation Not connected paired Colour Type Energized White Permanent Selected in TuneWISE White Flashing fast Prepared to be added to the system White Flashing slowly To be...

Page 12: ...t Cleaning Ideally the product should be cleaned twice a year by vacuuming the coil to remove loose dust In fibre dense environments a more frequent interval is recommended A simple visual inspection...

Page 13: ...ission standard for residential commercial and light industrial environments EN 300 328 V1 9 2 V1 9 1 V1 8 1 Electromagnetic compatibility and Radio spectrum Matters ERM Wideband Transmission systems...

Page 14: ...WISE Parasol Zenith b 14 Swegon reserves the right to alter specifications 20 06 2019 Maintenance 4 2 3 1 6 5 942428035...

Reviews: