Swegon WISE Parasol EX 1290 Instructions For Use Manual Download Page 12

WISE 

Parasol EX

12

Swegon reserves the right to alter specifications.                          23/11/2017

 

A18, B17

A19, B18

Summary of Contents for WISE Parasol EX 1290

Page 1: ...installation 4 Water 6 Air 7 Commissioning 8 Nozzle setting 8 ADC 8 Connections 9 WISE Parasol EX with factory fitted components 9 Factory fitted components as an option 9 LED Explanation 9 Installati...

Page 2: ...e Electrical data It is not permissible to insert foreign objects into the product s contactor connections or ventilation openings risk for short circuiting 24 V isolation transformer to be connected...

Page 3: ...the sensor module WISE SMB is installed in the face plate the height meas urement H increases by 12 mm Dimensions WISE Parasol EX 1290 Dimensions mm A B C D E F G H 1170 567 198 70 280 1290 690 230 1...

Page 4: ...WISE Parasol EX 4 Swegon reserves the right to alter specifications 23 11 2017 Installation base module Suspension A1 B1 A1 B1 B2 A2 B Surface mounted installation A Suspended installation...

Page 5: ...5 23 11 2017 Swegon reserves the right to alter specifications WISE Parasol EX A3 B3 B4 M8 A4 A5...

Page 6: ...Supply pipe Plain pipe 12x1 0 mm A only Cooling Return Plain pipe 12x1 0 mm Supply pipe Plain pipe 12x1 0 mm B Cooling Heating Return Plain pipe 12x1 0 mm Supply pipe Plain pipe 12x1 0 mm V rme retur...

Page 7: ...7 23 11 2017 Swegon reserves the right to alter specifications WISE Parasol EX Connection dimensions Unit WISE Parasol EX 690 MF 125 WISE Parasol EX 1290 HF 125 Air...

Page 8: ...an shape X shape WISE Parasol EX is a part of the WISE system that demand controls both air and water on a room level and guarantees the highest level of indoor climate with minimum energy consumption...

Page 9: ...ling on the pipes Supplied but requires easy installation on the face plate Cable for connection of WISE SMB is prefitted on the base module and connected on WISE CU but requires the cable to be conne...

Page 10: ...WISE Parasol EX 10 Swegon reserves the right to alter specifications 23 11 2017 A11 B10 A12 B11 TORX T 25 1 x 8 A13 B12 A14 B13 Installation design module Click...

Page 11: ...11 23 11 2017 Swegon reserves the right to alter specifications WISE Parasol EX A15 B14 A16 B15 A17 B16 Click...

Page 12: ...WISE Parasol EX 12 Swegon reserves the right to alter specifications 23 11 2017 A18 B17 A19 B18...

Page 13: ...duct should be cleaned twice a year by vacuuming the coil to remove loose dust In fibre dense environments a more frequent interval is recommended A simple visual inspection of connections is recommen...

Page 14: ...ards Emission standard for residential commercial and light industrial environments EN 300 328 V1 9 2 V1 9 1 V1 8 1 Electromagnetic compatibility and Radio spectrum Matters ERM Wideband Transmission s...

Page 15: ...15 23 11 2017 Swegon reserves the right to alter specifications WISE Parasol EX Maintenance 1 2 4 5 7 7 3 6 Click Opens side A or B A B...

Page 16: ...WISE Parasol EX 16 Swegon reserves the right to alter specifications 23 11 2017 942428036...

Reviews: