background image

B

AxA

Figure 7. HAWK Ca with ALS. CL = Centerline.

Figure 9. SARb K frame.

1

Figure 8. HAWK Ca with ALS. Low installation height.

Figure 6. HAWK Ceiling

Dimensions and Weights

HAWK Ceiling

Size

A

ØD

ØD1

I

M

Weight, kg

125-600

595

340

124

575

70

3.5

160-600

595

340

159

575

70

3.5

200-600

595

420

199

575

70

3.5

250-600

595

500

249

575

70

3.5

315-600

595

500

314

575

50

3.5

400-600

595

500

399

575

50

3.5

Dimensions of opening in ceiling = l x l

HAWK Ceiling with ALS – 1 step

Size

A

B

C

ØD

Ød

E1

E2

125-600

595

282

217

99

125

255

212

160-600

595

342

252

124

160

279

236

200-600

595

404

288

159

200

314

271

250-600

595

504

332

199

250

354

311

315-600

595

622

388

249

315

395

352

400-600

595

767

488

314

400

455

Size

F1

F2

G1

G2

H

K

Weight, kg

125-600

113

70

175

132

270

80

5.5

160-600

113

70

188

145

315

80

6.2

200-600

113

70

205

162

375

100

7.0

250-600

113

70

225

182 465

115

8.7

315-600

93

50

230

187

575

140

11.8

400-600

93

262

712

175

15.0

HAWK Ceiling with ALS – 2 steps

Size

A

B

C

ØD

Ød

E1

E2

160-600

595

342

252

99

160

255

212

200-600

595

404

288

124

200

279

236

250-600

595

504

332

159

250

314

271

315-600

595

622

388

199

315

334

291

Size

F1

F2

G1

G2

H

K

Weight, kg

160-600

113

70

175

132

315

80

5.5

200-600

113

70

188

145

355

80

4.2

250-600

113

70

205

162

450

100

7.0

315-600

93

50

205

162

550

115

8.7

CL = Center line

3

20180814                    Swegon reserves the right to alter specifications.

HAWK 

Ceiling

Summary of Contents for HAWK Ceiling a

Page 1: ...kets The distance between the commissioning box and the air diffuser can be increased by as much as 500 mm with an ordinary circular duct without having to lengthen the measuring tubes and damper adjustment cords See Figures 3 and 4 Commissioning Commissioning should be carried out with the air diffuser face mounted Pull the measuring tubes and damper adjustment cords out through the air diffuser ...

Page 2: ... commissioning box with low installation height Figure 3 Installation alternatives Figure 2 Quick Access Installation Figure 5 To dismantle the damper 0xD 5 0xD 5 2xD 10 HAWK Ceiling 2 Swegon reserves the right to alter specifications 20180814 ...

Page 3: ...1 250 600 595 504 332 199 250 354 311 315 600 595 622 388 249 315 395 352 400 600 595 767 488 314 400 455 Size F1 F2 G1 G2 H K Weight kg 125 600 113 70 175 132 270 80 5 5 160 600 113 70 188 145 315 80 6 2 200 600 113 70 205 162 375 100 7 0 250 600 113 70 225 182 465 115 8 7 315 600 93 50 230 187 575 140 11 8 400 600 93 262 712 175 15 0 HAWK Ceiling with ALS 2 steps Size A B C ØD Ød E1 E2 160 600 5...

Page 4: ...ue 200 250 250 500 28 4 Red 200 250 250 600 32 5 28 5 Red 200 315 315 500 30 3 Blue 250 315 315 500 31 8 Red 200 315 315 600 37 0 34 2 Blue 250 315 315 600 39 4 35 3 Red 315 400 400 600 50 9 Red Number of measuring tubes 1 Extract air ALSd HAWK C extract air Size Size Standard Colour of the tube 200 250 250 600 19 1 Transparent 250 315 315 600 25 4 Transparent 315 400 400 600 34 9 Transparent Numb...