background image

4

SDHE.040219

Swegon reserves the right to make changes.

www.swegon.com

Air flow

Pr

essur

e dif

fer

ential, Pa

FLK12

FLK16

FLK20

FLK25

FLK31

H

205 mm

235 mm

275 mm

325 mm

390 mm

B

215 mm

265 mm

315 mm

365 mm

425 mm

D

125 mm

160 mm

200 mm

250 mm

315 mm

K

140 mm

155 mm

180 mm

230 mm

320 mm

L

252 mm

267 mm

302 mm

352 mm

452 mm

Direction of airflow

B

H

D

K

L

Dimensions for FLK duct filter

Pressure loss in FLK duct filter with G4-filter

12

16

20

150

100

50

0

0

50

100

150

200

250 300

350

400

450

500 550

l/s

600

25

31

Dimensions and technical data

270

370

Technical data

Model 

  

mm

Capacity  

kW

Minimum airflow 

l/s       m

3

/h 

SDHE125-1T

125

1,2

19

70

SDHE160-1T

160

1,2

  31

110

SDHE200-1T

200

1,2

  47

170

SDHE250-1T

250

1,2

75

270

SDHE250-2T

250

2,0

75

270

SDHE315-1T

315

1,2

115

415

SDHE315-2T

315

2,0

115

415

Dimensions for duct heater

Summary of Contents for CASA SDHE125-1T

Page 1: ...ovisions Products For 125 mm ducts SDHE125 1T LVI nro 7906723 Electric duct heater 1 2 kW 300H125 12 1 SET connection unit For 160 mm ducts SDHE160 1T LVI nro 7906724 Electric duct heater 1 2 kW 300H160 12 1 SET connection unit For 200 mm ducts SDHE200 1T LVI nro 7906725 Electric duct heater 1 2 kW 300H200 12 1 SET connection unit For 250 mm ducts SDHE250 1T Electric duct heater 1 2 kW 300H250 12 ...

Page 2: ...enclosure NOTE Make sure that the strain relief is arranged for the connections according to the electrical safety directives 2 Electric and control cables Smart Extension Temperature module Sensor T6 T7 T8 T9 Smart unit SET2 SET1 DI max 50 VDC NC NC NC 1 2 3 4 5 6 7 8 9 10 11 12 max 250 V 6 A Relay 1 4 3 2 1 max 250 V 6 A Relay 2 NC 4 3 2 1 AO3 AO2 AO1 NC NC NC SET 1 0 230V 2 1 3 4 5 7 8 9 10 1 A...

Page 3: ... cal safety directives in a separate enclosure NOTE Make sure that the strain relief is arranged for the connections according to the electrical safety directives 2 Electric and control cables Smart Extension Temperature module Sensor T6 T7 T8 T9 Smart unit SET2 SET1 DI max 50 VDC NC NC NC 1 2 3 4 5 6 7 8 9 10 11 12 max 250 V 6 A Relay 1 4 3 2 1 max 250 V 6 A Relay 2 NC 4 3 2 1 AO3 AO2 AO1 NC NC N...

Page 4: ... mm 452 mm Direction of airflow B H D K L Dimensions for FLK duct filter Pressure loss in FLK duct filter with G4 filter 12 16 20 150 100 50 0 0 50 100 150 200 250 300 350 400 450 500 550 l s 600 25 31 Dimensions and technical data 270 370 Technical data Model mm Capacity kW Minimum airflow l s m3 h SDHE125 1T 125 1 2 19 70 SDHE160 1T 160 1 2 31 110 SDHE200 1T 200 1 2 47 170 SDHE250 1T 250 1 2 75 ...

Reviews: