![Swegon CASA R85 Instructions For Installing Download Page 4](http://html1.mh-extra.com/html/swegon/casa-r85/casa-r85_instructions-for-installing_1413527004.webp)
Swegon reserves the right to alter specifications.
4 www.swegon.com/casa
R85.190814
If the ventilation unit is reset to its
original factory settings, you will have to
program the unit again as described above.
The installation work, the entering of set-
tings and commissioning should be carried
out by qualified personnel only.
After you have connected the reheating cassette, you will have
to change the operational settings of the ventilation unit. You
can change the parameters from the Premium control panel in
the following way:
To activate the reheating function
• Go from the basic image by pressing the
Menu
button to
reach the
Main menu
• Select
Install and service
and press
Select
• Enter the code: 1234, and confirm by pressing the
Set
but-
ton
• In the Installation and service menu, select
Functions
and
press
Select
• Select
Heating
and press
Select
• Select
On
and press the
Set
button
• Leave the menu by pressing the
Return
button an appropri-
ate number of times
To commission the reheater
• Go from the basic image by pressing the
Menu
button to
reach the
Main menu
• Select
Install and service
and press
Select
• Enter the code: 1234, and confirm by pressing the
Set
but-
ton
• In the Installation and service menu, select
El.heaters
and
press
Select
• Select
Reheater
and press
Select
• Select
On
and press the
Set
button
• Leave the menu by pressing the
Return
button an appropri-
ate number of times
Control diagram
Supply air
Delivery demarcations
Electrical distribution box
Outside
air
Exhaust air
Group electrical distribution box
Extraction, cooker hood
Extract air
Kitchen
12.