4 CONTROL AND MAINTENANCE OF THE STARTING PLATFORM
4.1 Control without application of pressure
Connect the buzzer to the connection cable. If there is no pressure on the platform (1), the
buzzer remains silent. If the buzzer emits a sound, proceed as described in paragraph
4.5.
4.2 Pressure sensitivity control
Press with the Dynamometer (2) against the middle of the platform (1). Read on the Dynamometer
(2) the pressure necessary to activate the buzzer. If the sensitivity is out of the range of 13kg and
18kg, see paragraph 4.7.
4.3 Connection to the timing system
If a satisfactory result has been obtained in test 4.1 and 4.2, connect the connection cable
to the timing system.