Safety Precautions

1. This product is intended for use in hospitals and dental clinics only. The use of the product must 

comply with the requirements of the relevant operating specifications and relevant regulations of the 

medical department. Users must be professionally trained and qualified as dentists or technicians. 

Do not look directly into the light output. Patient, clinician and assistants are always suggested 

wearing protectors (safety goggle, face shield…) to avoid crossing infection.

2. The products are reusable:

Prior to each use, place a new barrier sleeve over the curing light Swan. The hygienic barrier sleeve 

is customs fitted to the curing light and keeps the surface of the curing light clean. The barrier sleeve 

helps prevent cross contamination, helps keep dental composite material from adhering to the 

surface of the lens and curing light, and prevent discoloration and corrosion from cleaning solutions. 

The curing lights must be cleaned and sanitized with appropriate cleaning and/or sanitizing agents 

after each patient. The sleeve is not equipped with the curing light. Please note that the sleeve must 

meet the requirements of relevant medical device regulation and it’s disposable.

3. During the operation, the light should be aimed straightly at the composite resin to ensure the 

effect of solidification.

4. Please use the original light hood and follow the right installation ways to avoid the damage of 

blue light to the eyes.

5. Please do not use other than the specified voltage to recharge the battery. Only the original 

pedestal charger, adapter and Lithium battery could be used, because other brand pedestal charger, 

adapter and Lithium battery are likely to damage the circuit.

6. Please recharge the battery at least 4 hours before first time usage. It’s forbidden to connect the 

charger to the base for long time while not charging and it’s not allowed to use the curing light while 

charging.

7. It is forbidden to touch the charging connector with metal or other conductor, to avoiding damage 

the circuit of charge or the battery.

8. Please recharge the battery in cool and ventilated room. Please press the main unit to the buckle 

of charging base, in order to avoid the poor connection.

9. It is forbidden to self-taking-apart the battery, in order not to result in short-circuit or leakage.

10. It is forbidden to extrude, shake or rock the battery. The Lithium battery is forbidden to be in 

short-circuiting situation and it is forbidden to put the battery with metal or other conductors.

11. The instrument has electromagnetic interference. Do not use it around electronic surgery, and 

use the instrument with caution in an environment with strong electromagnetic interference.

12. This product does not contain toxic or hazardous substances and it is discarded in accordance 

with the relevant laws and regulations on waste medical devices. Please deal with the replaced 

battery according to national regulations

13. As a professional manufacturer of medical instruments, we are only responsible for the safety 

on the following conditions:

• The maintenance, repair and modification are made by the manufacturer or the authorized dealer.

• The changed components are original of our company and operated correctly according to 

instruction manual.

Product contraindications:

The heart disease patient, pregnant woman, children and the person who are allergic to blue light 

should be cautious to use this equipment.

Symbol instruction

Symbol

Instruction

Symbol

Instruction

Warning, Caution and Important! 

Check the Instruction Manual

Consult the accompanying 

documents

Date of manufacture

Manufacturer

According to the type of protection 

against electric shock: CLASS II 

EQUIPMENT

According to the degree of 

protection against electric 

shock:Type B applied part

Screw inside/ outside

Used indoor only

Recovery

Keep dry

Handle with care

Atmospheric pressure for storage

Temperature limitation for storage

Humidity limitation for storage

Appliance compliance WEEE directive, 

Dispose as required by the law.

CE Mark

Summary of Contents for CURING LIGHT

Page 1: ...Instruction Manual Please read this manual before operating RF SWA M001 1 1 20210506 ...

Page 2: ...le charging 7 It is forbidden to touch the charging connector with metal or other conductor to avoiding damage the circuit of charge or the battery 8 Please recharge the battery in cool and ventilated room Please press the main unit to the buckle of charging base in order to avoid the poor connection 9 It is forbidden to self taking apart the battery in order not to result in short circuit or leak...

Page 3: ...ccessories Period of replacement Method of replacement Power adapter Damaged Replace directly according to the requirements of the manual Charging base Damaged Replace directly according to the requirements of the manual Battery Damaged Take out the damaged battery and replace it with a new one Light hood Damaged Replace directly according to the requirements of the manual 3 Technical parameters 3...

Page 4: ...mode key to select time see table 1 for settable curing time 5 4 Point the light guide rod front connector light source at the right position press the switch button and there s a beep The curing light will start to work as the mode setting The display screen starts counting down from the selected time and after the timing ends the display screen displays the setting time 5 5 Before the end of set...

Page 5: ...pacity of battery decreased Change a new battery The mode indicator twin kles when charging Low voltage Back to normal after 15 minute charging If the fault still cannot be resolved please contact your local dealer or our company 9 Electromagnetic compatibility Attention This Curing Light meets the relevant requirements of YY 0505 standard electromagnetic compatibility The basic performance of the...

Page 6: ... ESD GB T 17626 2 8 kV contact 15 kV air 8 kV contact 15 kV air Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30 Electrical fast transient burst GB T 17626 4 2kV for power supply lines 1 kV for Input output lines 2kV for power supply lines Mains power quality should be that of a typical commercial or hospital e...

Page 7: ...of the transmitter W The distance between different frequencies of the transmitter 150kHz to 80MHz d 1 2 P1 2 80MHz to 800MHz d 1 2 P1 2 800MHz to 2 5GHz d 2 3 P1 2 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 22 3 2 3 10 3 8 3 8 7 3 100 12 12 23 For the maximum rated output power of the transmitter not listed in the above table the recommended separa tion distance d which in meters m that can b...

Page 8: ...uct technology or accessories operation manual and machine packaging content at any time without prior notice The product is subject to the real object and the picture is for reference only The final interpretation right belongs to Guilin Refine Medical Instrument CO LTD After service and Warranty Instruction 1 Period validity two year s free repair for the main unit charging base power adapter fr...

Page 9: ...9 ...

Page 10: ...10 ...

Reviews: