Summary of Contents for Chematest 30

Page 1: ...Chematest 30 Version 1 00 and higher A 96 730 101 151118 Operator s Manual...

Page 2: ...d staff of technical specialists around the world For any technical question contact your nearest SWAN representative or the manufacturer SWAN ANALYTISCHE INSTRUMENTE AG Studbachstrasse 13 8340 Hinwil...

Page 3: ...ds 8 3 2 Instrument Specification 9 3 3 Scope of Supply 10 4 Parts and Controls 11 4 1 Instrument Overview 11 4 2 Keys 12 4 3 Display 13 5 Initial Setup 14 6 Measuring 15 6 1 Performing a Measurement...

Page 4: ...2 A 96 730 101 151118 Chematest 30 10 Part Numbers 29 10 1 Reagents 29 10 2 Accessories 30 10 3 Spare Parts and Consumables 30 11 Notes 31...

Page 5: ...Warning notices The symbols used for safety related notices have the following meaning WARNING Severe injuries or damage to the equipment can occur if such warnings are ignored Follow the prevention i...

Page 6: ...operation and when charging the instrument Only charge the instrument using a standard type A USB socket and the supplied USB cable Protect from heat and splash water during charging not IP67 Do not...

Page 7: ...condensation If condensation occurs on the cuvette cold sample in a warm envi ronment wipe it off and carry out the measurement as quickly as possible Observe proper sampling Take the water samples a...

Page 8: ...1a the other contains the solvent DPD 1b Before use fill the contents of DPD 1b into DPD 1a close the bottle with the drop counter and shake firmly until the DPD powder has completely dissolved Write...

Page 9: ...combined chlorine with one cuvette or with two cu vettes Apart from the fact that one or two cuvettes are used the two methods are identical Measuring with only one cuvette is faster and requires less...

Page 10: ...ge Displayed as Chlorine Free chlorine 0 10 ppm ppm mg l Total chlorine 0 10 ppm ppm mg l Combined chlorine using one cuvette 0 10 ppm ppm mg l Combined chlorine using two cuvettes 0 10 ppm ppm mg l F...

Page 11: ...ing not IP67 Charging time approximately 3 hours Battery life approximately 5000 measurements or one week of standby operation Automatic shutoff after 10 minutes of inactivity Conditions for operation...

Page 12: ...upply A B C D E Carrying case 10 ml syringe Dropper bottle for rinsing water Brush for cuvette cleaning Wipes for cuvette cleaning F G H I 2 glass cuvettes Blister pack for reagent bottles Chematest 3...

Page 13: ...Chematest 30 Parts and Controls A 96 730 101 151118 11 4 Parts and Controls 4 1 Instrument Overview A B C Charging socket Cuvette adapter Display D E F Keypad Cuvette cap Cuvette A B C D E F...

Page 14: ...or off the instrument B ARROW UP to move up in a menu list and to increase digits C ARROW DOWN to move down in a menu list and to decrease digits D EXIT to exit a menu or command to move back to the p...

Page 15: ...It is also possible to set the currently displayed methods as a static list see Method save p 28 B Method catalogue List of all available methods C Menu Access to further instrument functions e g disp...

Page 16: ...thods in detail reagents required order of addition etc activate the expert mode Otherwise leave the expert mode disabled and the instrument will guide you step by step through each measurement Naviga...

Page 17: ...ment Step 3 Display and storage of the measured results For de tails on the result screen see example on 17 The methods differ mainly in the following points Different reagents are required depending...

Page 18: ...e Place the adapter in the Chematest and close the cap Enter for zero 83 Free chlorine Measuring zero Wait for instructions Enter Enter 83 Free chlorine Remove adapter with cuvette and open the cap En...

Page 19: ...can also be completely deactivated see 26 Select an ID from the list Select a user from the list Select Enter to continue and confirm with Enter The ID and the user are added to the measurement in th...

Page 20: ...ve power The automatic shutoff has the same effect on the saving of measurement results as pressing the Exit key See Step 3 Display of the results p 17 for details 6 3 Recalling Stored Measurement Dat...

Page 21: ...to be set in menu Settings Sensors Photometer The refer ence values are specified in the enclosed calibration certificate Verification procedure Before each use check the expiration date on the calib...

Page 22: ...with water Photometer compartment The photometer compartment can be easily cleaned if water or re agents have been spilled Turn the unit to the rear loosen the two screws A and remove the cover B Use...

Page 23: ...Time and Date The correct setting of the clock is important for the identification of the stored measurements It is therefore recommended to check the date and time setting regularly The time and dat...

Page 24: ...ror List Error Description Corrective action E001 Bluetooth Switch the instrument on and off and check if the error disappears If the error persists call support E002 IC ADC Call support E003 Factory...

Page 25: ...aneous light Make sure that the cuvette cap is properly closed Cuvette dirty Clean and rinse the cuvette Residues of reagents Clean and rinse the cuvette Lenses dirty Open the photometer compartment a...

Page 26: ...d value s ID User If the fields ID and User contain the text Empty the assignment of the attributes to the measurement was skipped by the user or generally deactivated under 4 2 Identification p 26 Up...

Page 27: ...N Serial number of the instrument Version Installed firmware version e g V1 00 11 18 Bootloader Installed bootloader version e g V 1 00 Factory test Test date of the instrument 2 3 Sensors Photometer...

Page 28: ...cutive measurements both LEDs off green LED on IR LED on 3 2 Verification Photometer See Verification p 19 3 3 Set Time Adjust date and time 4 Settings 4 1 Sensors Photometer Enter the reference value...

Page 29: ...Ver Deletes the user calibration of all electrodes not relevant for Chematest 30 and all recorded verification measurements All other values are kept in memory Data History Deletes all recorded measur...

Page 30: ...st three lines of the main menu display the last three methods selected from the method catalogue Alternatively the currently displayed entries can be defined as a static list No Displays a static lis...

Page 31: ...Chlor Free chlorine Total chlorine Combined chlorine A 85 590 400 Oxycon Des Free chlorine Free chlorine in presence of chlorine dioxide or bromine Chlorine dioxide Bromine Iodine A 85 590 500 Oxycon...

Page 32: ...rying case for Chematest 30 A 70 065 630 Cuvette adapter with cap A 70 065 631 Glass cuvettes 10 pack A 70 065 633 Spare part set consisting of 1 dropper bottle 125 ml 3 disposable syringes 10 ml 3 di...

Page 33: ...Chematest 30 Notes A 96 730 101 151118 31 11 Notes...

Page 34: ...32 A 96 730 101 151118 Chematest 30 Notes...

Page 35: ...Chematest 30 Notes A 96 730 101 151118 33...