A-96.250.211 / 171121
AMI Sodium P
Default Values
114
11. Default Values
Note:
The <Maintenance>/<Regeneration> menu is only visible
if the automatic regeneration option is installed.
Maintenance:
Regeneration
Start time .............................................................................. 01:00:00
Calendar: Monday to Sunday:........................................................Off
Duration:.......................................................................................20 s
Delay: .........................................................................................300 s
Signal Outputs:.............................................................................hold
Output/Control: .............................................................................hold
Operation:
Sensors
Filter Time Const.: ......................................................................180 s
Hold after Cal.:............................................................................300 s
Alarm Relay
.........................................................................same as in Installation
Signal Output
.........................................................................same as in Installation
Relay 1 and 2
.........................................................................same as in Installation
Input
.........................................................................same as in Installation
Logger
Logger Interval:........................................................................ 30 min
Clear Logger:.................................................................................. no
Installation:
Sensor
Sensor type: ........................................................................... Sodium
Temperature: ............................................................................. NT5K
Channel switch: .......................................................................... none
Standard: Standard 1: ........................................................... 200 ppb
Standard: Standard 2: ......................................................... 2.00 ppm
Signal Output 1
Parameter:........................................................................... Sodium 1
Current loop:........................................................................4 - 20 mA
Function:.....................................................................................linear
Scaling: Range low:.............................................................. 0.00 ppb
Scaling: Range high: ........................................................... 1.00 ppm
Signal Output 2
Parameter:...................................................................... Temperature
Current loop:........................................................................4 - 20 mA
Function:.....................................................................................linear
Scaling: Temperature: Range low:........................................... 0.0 °C
Scaling: Temperature: Range high: ........................................ 50.0 °C
Further Parameters:
Scaling: pH: Range low: ........................................................0.00 pH