7
OPERATION
The Digital display has numerous functions:
1. When the unit is plugged in, it will indicate the room humidity level.
2. When you set the humidity, it will indicate the humidity that you have
selected
3. When you program the time for the unit to turn on and off, it will
show the hours.
4. When the room humidity is lower than 35%, it will show “35”
5. When the room humidity is higher than 95%, it will show “95”
OPERATING INSTRUCTIONS
The buzzer will sound several times when the unit is powered on. The LED will show
the room humidity for 3 seconds, then it will automatically turn off.
1.
Turn on/off
, press:
2.
Humidity setting
, press: Then press: or to select humidity level.
40% to 80%, in 5%, increments. The LED display will flash when adjusting. Stop
pressing for 5 seconds, it will return to normal display. The default value of humidity
is 55%.
3.
Fan speed setting
, press: Press repeatedly to cycle through the fan speeds.
The corresponding LED light will illuminate.
4.
Swing setting
, press: After the machine has started the louvres will swing
back and forth. Press again to stop.
5.
Timer setting
, press: when the unit is stopped, then press or to set
start time
. Start time range is between 1 - 24 hours.
To set
run time
: With machine running press then press or to set how
long the unit will run for before it switches itself off. Run time range is 1 - 24 hours.
Please note
: if the tank gets full during the selected run time, the unit will stop, a
buzzer will sound and the tank full indicator will illuminate.
SH16810N_IM.indd 7
06/05/2020 09:23