Page 18
WALK-IN TUB MANUAL
OPERA
TING INSTRUCTIONS
5701 NW 35 Avenue Miami, FL 33142 • Phone 866-633-4882 • Fax 866-560-1060
OPERATING SAFETY INSTRUCTIONS
CONTINUED
The unit must be connected only to a supply circuit that is protected by a ground-fault circuit-interrupter (GFCI). Such a GFCI should
be provided by the installer and should be tested on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt
power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, there may be a ground current
flowing, indicating the possibility of an electric shock. Do not use this massage bathtub. Disconnect the jet massage bathtub and
have the problem corrected by a qualified service representative before using.
To reduce the risk of electrical shock, the dedicated electrical supply circuit(s) must be grounded. To do this, connect the third leg of
the 3-conductor wiring cable to the grounding terminal of the electrical service panel and run continuously to the green grounding
screw on the GFCI or electrical receptacle in the wiring compartment.
IN-LINE HEATERS
If your bathtub is equipped with an in-line heater, it will operate only when the pump is on.
NOTE: THE IN-LINE HEATER IS DESIGNED TO KEEP YOUR WATER WARMER LONGER, BUT IS NOT DESIGNED TO INCREASE
THE WATER TEMPERATURE. HEAT SETTINGS ARE NOT ADJUSTABLE.