Figure 3
Admissible Voltage Drop
Type of lead
Admissible voltage in
insulated CU lead
Admissible voltage drop
in the entire circuit
Lamp leads from light switch Terminal
30 to lights < 15 W or to the trailer
socket and from there to the lights
0.1 V
0.6 V
From light switch terminal 30 to
Lights < 15W or to trailer socket
0.5 V
0.9 V
From light switch terminal 30 to
Headlights
0.3 V
0.06 V
From control leads from switch
to relay, horn, wiper etc.
0.5 V to 12 V
2.0 V to 24 V
1.5 V to 12 V