background image

6. CONNECTION

OVP-15P voltage relay is connected to a standard socket of 230 V / 50 Hz 

power  supply  network.  The  socket  must  be  rated  at  the  current  16  А.

 

Protected devices are connected to the output socket of OVP-15P. 

The  voltage  relay  is  designed  for  operation  indoor  only.  The  device 

operation is inadmissible in places with high humidity and where ingress of 

liquid on its case is possible. Ambient temperature during the voltage relay 

operation must be in the range +10 to +35 °С.

7. OPERATION

The voltage relay has the following operation modes:

• 

normal operation;

• 

protection mode;

• 

turn-on delay mode.

The voltage relay is in normal operation, when the active voltage of the power 

supply network is within 199–252 V limit and the turn-on delay time is over. 

In  this  mode  the  protected  equipment  connected  to  the  relay  is 

de-energized, the indicator

 

b

 

lights continuously.

If  the  voltage  exceeds  the  set  thresholds,  the  relay  enters  the  protection 

mode. In this mode the equipment connected to the relay is de-energized 

and  one  of  protection  indicators  starts  to  light:

 

c

 

when  high  voltage 

protection is 

actuated or 

a

 

when low voltage protection is actuated. The 

 

voltage relay will be in this mode as long as the supply voltage attains a value 

within 204–244 

V

 ± 2%  range.

The relay enters the turn-on delay mode after its connection to the power 

supply  network  or  when  it  leaves  the  protection  mode.  In  this  mode  the 

equipment connected to the relay remains de-energized till the end of delay 

time, and the indicator 

b

 blinks during this time. The turn-on delay value 

for 

OVP-15P voltage relay is180 sec.

Force transition from the turn-on delay mode to the operation mode can be 

done by pressing the button 

d

.

ENG

6

Voltage Relay

Summary of Contents for OVP-15P

Page 1: ...USER S MANUAL www sven Voltage Relay OVP 15P...

Page 2: ...STRICTION Despite the exerted e orts to make this Manual more exact some discre pancies may occur The information in this Manual is given on as is terms The author and the publisher do not bear any li...

Page 3: ...t is prohibited to open and repair the device on your own It is prohibited to open and repair any protected equipment if it is con nected to the device socket It is prohibited to use the device with m...

Page 4: ...ication Protective shutters in the output socket Protective grounding contacts fusible safety device 15 5 TECHNICAL DESCRIPTION OVP 15P voltage relay presents a device with an electronic circuit with...

Page 5: ...nce voltage range cIndicator is high entrance voltage range d ON button of a force connecting of loading e Wall plug to connect the voltage relay to 230 V 50 Hz power supply network socket f Protectiv...

Page 6: ...mode the protected equipment connected to the relay is de energized the indicator b lights continuously If the voltage exceeds the set thresholds the relay enters the protection mode In this mode the...

Page 7: ...on threshold to increase power supply voltage V Output socket Dimensions mm Weight kg Coulor Value 100 280 50 15 0 max 3 3 0 3 sec 125 4500 199 2 252 2 1 7 4 72 2 87 7 78 0 126 white 8 TECHNICAL SPECI...

Page 8: ...47 48310 15 Manufacturer SVEN PTE LTD 176 Joo Chiat Road 02 02 Singapore 427447 Produced under the control of Oy Sven Scandinavia Ltd 15 Kotolah dentie Kotka Finland 48310 Made in China Registered Tra...

Reviews: