SV 100A User Guide

SV

 

100A Technical Specification

The policy of our company is to continually innovate and develop our products.
Therefore, we reserve the right to change the specifications without prior notice.

Application

 

     

Whole-body

Standards

 

     

ISO 8041:2005, ISO 2631-1:1997

Meter Mode

       

aw (RMS), awmax (RMS MAX), VDV, MaxVDV,

 

awv (VECTOR), A(8) Daily Exposure,  A(8) Daily Exposure, 

 

 

       

ELV Time (TIME LEFT TO LIMIT), ELV Time (TIME LEFT TO LIMIT), EAV Time (TIME LEFT TO ACTION)

 

 

       

EAV Time (TIME LEFT TO ACTION); MTVV, Max, Peak, Peak-Peak

Filters

 

     

Wd, Wk, Wm, Wb (ISO 2631) and corresponding Band Limiting filters 

 

 

       

Wf for motion sickness filter measurements according to ISO 2631-1 (option)

RMS & RMQ Detectors

 

Digital true RMS & RMQ detectors with Peak

 

detection, resolution 0.1 dB 

Measurement Range

    

0.01 ms

-2

 RMS ÷ 157 ms

-2

 PEAK

Frequency Range

      

0.1 Hz ÷ 180 Hz

Data Logger

 

     

Time-history data including meter mode results and spectra

Time-Domain Recording

 

Simultaneous 3-channel time-domain signal recording (option)  

Analyser

 

     

1/1 octave real-time analysis (option) 

 

 

       

1/3 octave real-time analysis (option)

Accelerometer

       

Built-in tri-axial MEMS based 

Display

 

     

OLED 128 x 32 pixels

Memory

  

8 GB

Interfaces

  

USB 2.0 client, Bluetooth

Keyboard

  

4 push buttons

Power Supply
 

 

 

Ni-MH rechargeable cells 

 

operation time > 24 hours

1

 

 

 

USB interface

    

500 mA HUB

Environmental Conditions
  

 

Temperature

  

from -10 

o

C to 50 

o

C

  

 

Humidity

  

up to 90 % RH, non-condensed

Dimensions

  

o/ 235mm x 12 mm  

Weight

  

0.5 kg

1dependent  on instrument operation configuration

Summary of Contents for SV100A

Page 1: ...SV100A Vibration Dosimeter User Guide...

Page 2: ...s in the SV 100A automatically detect the presence of a user or vehicle driver which enables real daily exposure calculations for the period of time when the user is in contact with the vibrating surf...

Page 3: ...lysis Veri cation of vibration sources Research and development SF 100A 3OCT 1 1 1 3 octave analysis Veri cation of vibration sources Research and development SF 100A WAV Time domain signal recording...

Page 4: ...settings using panels on the right hand side 8 Disconnect the USB cable Instrument is ready to measure SV 100A User Guide 4 2 Connect the USB cable to PC Make sure the Supervisor software and USB dri...

Page 5: ...100A on the SA111 x axis vertical Set up of SV 111 5 Start the calibrator using level of 1 m s2 at 16 Hz and wait until all 3 LEDs are green SV 100A User Guide 5 4 Enable Calibration menu in SV 100A b...

Page 6: ...ndroid smarphone 3 Start the application The Assistant will ask you to enable Bluetooth and Localization services on your smartphone tablet 4 The Assistant will detect the SV100A automatically Install...

Page 7: ...open file simply double click on it SV 100A User Guide 7 2 Select files you wish to download and click the Download button located in the bottom section 3 Once the file is downloaded it will be automa...

Page 8: ...s website Service Office 48 22 51 88 320 or 48 22 51 88 322 Office hours are 9 00 a m to 5 00 p m Central European Time E mail at office svantek com Internet at www svantek com Address SVANTEK Sp z o...

Page 9: ...nding Band Limiting filters Wf for motion sickness filter measurements according to ISO 2631 1 option RMS RMQ Detectors Digital true RMS RMQ detectors with Peak detection resolution 0 1 dB Measurement...

Reviews: