Svane Electronic ApS Anti-burglary Smoke Generator INSTRUCTION MANNUAL
9
6.3 Installation note:
1) Install the product in the walls to the recommended distance of 2.5 meters high
orinstallation not exceed 3 meters from the ground.
2) Please direct the smoke towards the goods or the area to be protected.
3)
Attention:
The product must be connected to a certified alarm system.
4) During the maintenance and installation phases, do not stand near the smoke exit
hole.After supplying do not touch the device because it is extremely hot!
7. Connection
1) Keep the short jumper not to be removed during the installation
process. The short black line identified in the figure.
2) Before connecting, make sure that the resistance between the two cables of the smoke
generator is within 3 ohms
±
10%.
Attention:
When using a multimeter, make sure that its
output current does not exceed 10mA.
3) Connect the electric wires(means of igntion) to the alarm output (non-polarized continuous
voltage) of the anti-theft control panel, respecting the electric current value required for
ignition.
4) Before you connect the smoke generator, at the end of the test the product using a light or