3. SETTINGS AND ADJUSTMENTS
22
[NMEA Output Instance]
Select the output instance for fuel
data.
[0] to [5]
Note:
The remaining fuel calculation is for reference purposes. Do not use the results for navigation
planning or emergency purposes. During an entire voyage, select one SMD7/9 for the calculation at
start-up and keep that unit powered. The calculation of remaining fuel is not done when the unit is
powered off.
[IF NMEA Setup tab]
[Select IF]
Select the interface unit to use.
-
[Category]
Select the category of the analog
sensor.
[Wind], [ST800/ST850], [Fuel],
[Fresh Water], [Waste Water],
[Live Well], [Oil], [Black Water]
[Resistance Full]
Set the resistance of the tank at
full.
[0 ohm] to [500 ohm]
[Resistance Mid]
Set the resistance of the tank at
half-full.
[0 ohm] to [500 ohm]
[Resistance Empty]
Set the resistance of the tank at
empty.
[0 ohm] to [500 ohm]
[Capacity]
Set the maximum capacity of the
tank.
[0] to [9999]
[Self Test]
Start a diagnostic test of the de-
vices connected via the IF NMEA.
-
[Refresh]
Refresh the list of connected de-
vices
-
[Rudder Setup] tab
[PORT/STBD Reversing]
Select whether or not to set port
and starboard in reverse.
[ON], [OFF]
[About] tab - [System Information]
[Software Version]
Software version for the SMD7/9.
[Boot Version]
Boot application version.
[Kernel Version]
Kernel application version.
[RootFS Version]
RootFS application version.
[C-MAP 4D LIB]
Method of cartography.
[Base Chart]
Type of chart used for Chart 1.
[About] tab - [Fish Finder Information]
[Serial Number]
Serial number of the connected transducer.
[Program Version]
Fish Finder program version.
[Boot Version]
Boot application version.
[FPGA Version]
FPGA version.
[FPGA Program Version]
FPGA program version.
[About] tab - [C-Weather Information]
[C-Weather]
C-Weather version.
[About] tab - [About OSS]
[About OSS]
Shows the open-source software information for your SMD7/9.
[About] tab - [Copyright]
[Copyright]
Shows the copyright information for your SMD7/9.
[Service] tab
[Open Test Page]
Open the diagnostics test page. A password is required to access this
menu.
Menu name
Description
Setting range/options
3. SETTINGS AND ADJUSTMENTS
23
3. Tap the [
u
] icon at the top-right corner of the menu to close the menu.
[Restore Defaults] tab
[Restore Default Settings]
Select whether or not to restore
the [Initial Setup] menu’s default
settings.
[Yes], [No]
[Restore All to Factory De-
faults]
Select whether or not to restore
all menu settings to default.
Note:
User settings are not affect-
ed by this menu.
[Yes], [No]
[Clear Memory] tab
[Clear]
Select whether or not to clear the
memory and restore all settings to
default.
Note:
All user settings and data
will also be cleared.
[Yes], [No]
Menu name
Description
Setting range/options
Summary of Contents for SMD7
Page 35: ...SMD7 Muiti Function Display OUTLINE DRAWING Tabletop mount REF No C4498 G01 A D 1...
Page 36: ...SMD7 Muiti Function Display OUTLINE DRAWING Flushmount REF No C4498 G02 A D 2...
Page 37: ...SMD9 Muiti Function Display OUTLINE DRAWING Tabletop mount REF No C4499 G01 A D 3...
Page 38: ...SMD9 Muiti Function Display OUTLINE DRAWING Flushmount REF No C4499 G02 C D 4...
Page 40: ......