ON-VEHICLE SERVICE
For overhauling of starting motor, it is recommended that compo-
nent parts should be cleaned thoroughly. However, yoke, armature
coil, over-running clutch, magnetic switch assembly, rubber or
plastic parts are NOT ALLOWED to be washed in degreasing tank
or with grease dissolving solvent. Those parts should be cleaned
by blowing air and wiping with cloth.
DISMOUNTING AND REMOUNTING
1) Disconnect postitive ( + ) and negative ( – ) battery lead cables
at battery.
2) Remove battery and battery tray.
3) Disconnect battery cable and magnetic switch lead wire (1)
from starting motor terminals.
4) Remove 2 starting motor mounting bolts (2).
5) Remove starting motor (3).
6) To install, reverse the above procedure.
3
1
2
DISASSEMBLY
NOTE:
Before disassembling starting motor, be sure to put match
marks at two locations (A and B) as shown in left figure so that
any possible mistakes can be avoided.
1) Remove nut (1) securing the end of field coil lead to terminal on
the head of magnetic switch.
1
2) Take off magnetic switch (1) from starting motor body by remov-
ing two mounting screws (2).
1
2
6G-6
CRANKING SYSTEM
Summary of Contents for RA410
Page 262: ...ENGINE MECHANICAL 6A4 3...
Page 388: ...ENGINE AND EMISSION CONTROL SYSTEM 6E1 23 Blank...
Page 392: ...ENGINE AND EMISSION CONTROL SYSTEM 6E1 27 Fig for Step 3 2 3 1...
Page 399: ...6E1 34 ENGINE AND EMISSION CONTROL SYSTEM Fig for Step 2...
Page 552: ...AUTOMATIC TRANSMISSION 7B 25...
Page 553: ...7B 26 AUTOMATIC TRANSMISSION...
Page 663: ...BODY SERVICE 9 21 BUMPERS Front bumper Rear bumper...
Page 761: ...Prepared by Overseas Service Department 1st Ed May 1998 Printed in Japan Printing May 1999 610...