1C-3 Engine Electrical Devices:
Oxygen Sensor Heater Inspection
S3RH0B1306012
1) Disconnect sensor connector.
2) Using ohmmeter, measure resistance between
terminals “V
B
” and “GND” of sensor connector.
If found faulty, replace oxygen sensor.
NOTE
Temperature of sensor affects resistance
value largely. Make sure that sensor heater is
at correct temperature.
Resistance of oxygen sensor heater
5.0 – 6.4
Ω
at 20
°
C (68
°
F)
3) Connect sensor connector securely.
Camshaft Position (CMP) Sensor Removal and
Installation
S3RH0B1306013
Removal
1) Disconnect negative cable at battery.
2) Disconnect CMP sensor connector.
3) Remove CMP sensor from cylinder head.
Installation
1) Check that O-ring is free from damage.
2) Check that CMP sensor and signal rotor teeth are
free from any metal particles and damage.
3) Install CMP sensor (1) to cylinder head.
Tightening torque
Camshaft position sensor bolt (a): 10 N·m (1.0
kgf-m, 7.5 lb-ft)
4) Connect connector to it securely.
5) Connect negative cable to battery.
Specifications
Tightening Torque Specifications
S3RH0B1307001
Reference:
For the tightening torque of fastener not specified in this section, refer to “Fasteners Information in Section 0A in
related manual”.
IYSY01131014-01
1
(a)
I3RH0B130005-02
Fastening part
Tightening torque
Note
N
⋅
m
kgf-m
lb-ft
IAC valve screw
3.5
0.35
2.5
Oil control valve mounting nuts
11
1.1
8.0
Oil gallery pipe No.1 bolts
30
3.0
21.5
Heated oxygen sensor
45
4.5
32.5
Camshaft position sensor bolt
10
1.0
7.5