7B-55 Air Conditioning System: Automatic Type
DTC B1502 (No.02): Inside Air Temperature Sensor and/or its Circuit Malfunction
S3RH0A7224012
Wiring Diagram
DTC Detecting Condition and Trouble Area
DTC Troubleshooting
4
1) With ignition switch ON position, check voltage between
“YEL/BLK” wire terminal and “BLK/RED” wire terminal at
outside air temperature sensor connector.
Is voltage about 3.5 V?
Go to Step 5.
“BLK/RED” wire open,
poor connection of
“BLK/RED” wire
terminal at HVAC
control module
connector, and/or HVAC
control module faulty.
5
1) Check outside air temperature sensor referring to
“Outside Air Temperature Sensor Inspection”.
Is outside air temperature sensor normal?
HVAC control module
faulty.
Outside air temperature
sensor faulty.
Step
Action
Yes
No
5V
ORN/BLK
BLK/RED
G77-11
G77-9
2
1
3
9
11
I3RH0A722008-01
1. HVAC control module
2. Inside air temperature sensor
3. HVAC control module connector “G77” (viewed from harness side)
DTC Detecting Condition
Trouble Area
• Inside air temperature signal is less than the specified (0.7 V). (Inside air
temperature is less than –15
°
C, 5
°
F.)
• Inside air temperature signal is more than the specified (3.3 V). (Inside air
temperature is more than 74
°
C, 165.2
°
F.)
• “ORN/BLK” and/or “BLK/RED” wire
faulty
• Inside air temperature sensor faulty
• HVAC control module faulty
Step
Action
Yes
No
1
1) Turn ignition switch OFF, and then disconnect inside air
temperature sensor connector referring to “Inside Air
Temperature Sensor Removal and Installation”.
2) Turn ignition switch ON, and then check voltage
between “ORN/BLK” wire terminal at inside air
temperature sensor connector and body ground.
Is voltage about 3.5 V?
Go to Step 4.
Go to Step 2.
2
1) Turn ignition switch OFF, and then disconnect HVAC
control module connector referring to “HVAC Control
Module Removal and Installation in Section 7A”.
2) Check resistance between “ORN/BLK” wire terminal at
inside air temperature sensor connector and “ORN/BLK”
wire terminal at HVAC control module connector.
Is resistance less than 1 M
Ω
?
Go to Step 3.
“ORN/BLK” wire open or
high resistance.
3
1) Check resistance between “ORN/BLK” wire terminal and
body ground.
Is resistance more than 1 M
Ω
?
Poor connection of
“ORN/BLK” wire
terminal at HVAC
control module
connector, and/or HVAC
control module faulty.
“ORN/BLK” wire shorted
to ground.
Summary of Contents for Liana RH413
Page 2: ......
Page 4: ......
Page 6: ......
Page 336: ...1K 4 Exhaust System...
Page 456: ...3D 4 Propeller Shafts...
Page 553: ...Automatic Transmission Transaxle 5A 5 4WD I3RH0A510002 01 1 Transfer...
Page 1044: ...8B 119 Air Bag System...
Page 1049: ...Table of Contents 9 v Roof Molding Components 9M 1 Splash Guard If Equipped Components 9M 2...
Page 1278: ...9M 3 Exterior Trim...
Page 1300: ...Prepared by 1st Ed Nov 2003 2nd Ed Feb 2007...
Page 1301: ...19 mm 99500 54G10 01E 99500 54G10 01E SERVICE MANUAL VOLUME 1 OF 2 SERVICE MANUAL VOL 1 OF 2...
Page 1302: ...27 mm 99500 54G10 01E 99500 54G10 01E SERVICE MANUAL VOLUME 2 OF 2 SERVICE MANUAL VOL 2 OF 2...