7B-11 Air Conditioning System: Manual Type
Scan Tool Data
S3RH0A7214009
As the data values given in the following are standard values estimated on the basis of values obtained from the
normally operation vehicles by using a scan tool, use them as reference values. Even when the vehicles are in good
condition, there may be cases where the checked values do not fall within each specifies data range. Therefore,
judgement as abnormal should not be made by checking with these data alone.
Scan Tool Data Definitions
TEMP CONT SWITCH:
Position of temperature control
selector of HVAC control module
MODE CONT SWITCH:
Position of airflow selector of
HVAC control module
FAN CONT SWITCH:
Position of air speed selector of
HVAC control module
FAN DESIRE VOLT:
Voltage for blower motor
AIR MIX POS SENSOR:
Input signal from position
sensor in temperature control actuator
MODE POS SENSOR:
Input signal from position
sensor in air flow control actuator
A/C CONT SIG (ON or OFF):
State of A/C indicator
lamp
BLOWER FAN LOAD (ON or OFF):
ON: Position of
blower speed selector is 1st or 2nd position / OFF:
Position of blower speed selector is more than 3rd
position.
AIR INTAKE MODE (FRE or REC):
State of air intake
mode
A/C INDICATOR LAMP (ON or OFF):
State of A/C
indicator lamp
REC INDICATOR LAMP (ON or OFF):
State of
recirculation air (REC) indicator lamp
FRE INDICATOR LAMP (ON or OFF):
State of fresh air
(FRE) indicator lamp
REAR DEF INDICATOR LAMP (ON or OFF):
State of
rear defogger indicator lamp
Scan Tool Data
Condition
Normal Condition / Reference Value
TEMP CONT SWITCH
Each reference value is relative to the position of
temperature selector of HVAC control module.
Max Cool, P1, P2 – P20, P21, Max Hot
MODE CONT SWITCH
Each reference value is relative to the position of air
flow selector of HVAC control module.
VENT, BI-LEVEL, FOOT, DEF-FOOT,
DEF
FAN CONT SWITCH
Each reference value is relative to the position of
blower speed selector of HVAC control module.
OFF, 1st, 2nd – 7th, 8th
FAN DESIRE VOLT
Reference value is relative to the position of blower
speed selector of HVAC control module.
0 – 15.5 V
AIR MIX POS SENSOR
Reference value is relative to the position of
temperature selector of HVAC control module.
about 1.0 V (Max Hot)
about 4.0 V (Max Cool)
MODE POS SENSOR
Reference value is relative to the position of airflow
selector of HVAC control module.
about 1.0 V (DEF)
about 4.0 V (VENT)
A/C CONT SIG
A/C system is ON.
ON
A/C system is OFF.
OFF
BLOWER FAN LOAD
Position of blower speed selector is 1st or 2nd
position.
ON
Position of blower speed selector is more than 3rd
position.
OFF
AIR INTAKE MODE
Fresh air (FRE) mode is activated.
FRE
Recirculation air (REC) mode is activated.
REC
A/C INDICATOR LAMP
A/C indicator lamp is lighted.
ON
A/C indicator lamp is not lighted.
OFF
REC INDICATOR LAMP
Recirculation air (REC) indicator lamp is lighted.
ON
Recirculation air (REC) indicator lamp is not lighted.
OFF
FRE INDICATOR LAMP
Fresh air (FRE) indicator lamp is lighted.
ON
Fresh air (FRE) indicator lamp is not lighted.
OFF
REAR DEF INDICATOR
LAMP
Rear defogger indicator lamp is lighted.
ON
Rear defogger indicator lamp is not lighted.
OFF
Summary of Contents for Liana RH413
Page 2: ......
Page 4: ......
Page 6: ......
Page 336: ...1K 4 Exhaust System...
Page 456: ...3D 4 Propeller Shafts...
Page 553: ...Automatic Transmission Transaxle 5A 5 4WD I3RH0A510002 01 1 Transfer...
Page 1044: ...8B 119 Air Bag System...
Page 1049: ...Table of Contents 9 v Roof Molding Components 9M 1 Splash Guard If Equipped Components 9M 2...
Page 1278: ...9M 3 Exterior Trim...
Page 1300: ...Prepared by 1st Ed Nov 2003 2nd Ed Feb 2007...
Page 1301: ...19 mm 99500 54G10 01E 99500 54G10 01E SERVICE MANUAL VOLUME 1 OF 2 SERVICE MANUAL VOL 1 OF 2...
Page 1302: ...27 mm 99500 54G10 01E 99500 54G10 01E SERVICE MANUAL VOLUME 2 OF 2 SERVICE MANUAL VOL 2 OF 2...