SUZUKI GENUINE ACCESSORIES
English_I-M 990E0-54P56-010 Rev00 03/09/2018
8
11. SETTING OF PARAMETERS
CAUTION
The system is factory configured, modify default settings only if strictly necessary!
Par. Parameters
Selectable Settings
Factory Settings
01
Volume of buzzer
0, 1, 2 (
Ref.1
)
2
02
Detection range - Central sensors
50 - 95 cm
90
03
Detection range - Outer sensors
50 - 95 cm
50
06
STOP zone - Central sensors
30 - 50 cm
50
07
STOP zone - Outer sensors
30 - 50 cm
30
11
Number of speed signal pulses
1 - 99
2
12
Delay of sensors deactivation
0 or
10 - 60 sec. (
Ref.2
)
00
15
Service display (testing)
0, 1, 3 (
Ref.3
)
0
16
Continuous detection - zones F1 and F2
0, 1
(Ref.4)
1
17 Sensitivity
1, 2, 3
(Ref.5)
1
Ref.1
: 0 = OFF
1 = Low
2 = High
Ref.2
: By setting “00” => the system is activated every time ignition is turned ON.
To disable => press the button on the LED receptacle.
To turn it back ON => press the same button again.
Ref.3
: 0 = OFF
1 = Distance from closest obstacle.
3 = Vehicle approx. speed (km/h, refer to parameter 11 to program).
Ref.4
: 0 = OFF
1 = ON
Ref.5
: 1 = Low
2 = Medium
3 = High
12. TESTING
a.
To enter in programming mode, press and hold for at least 2 seconds one of the two buttons on the control unit (4).
b.
Select parameter “15” (see “Setting of parameters”).
c.
Press and hold one of the two buttons and select the test: “1” to test sensors or “3” to detect speed.
d.
Press and hold one of the two buttons; the display will show “--”.
e.
Test the sensors; the system will indicate the actual distance.
f.
Reset parameter to “00”.
g.
When testing is completed, press and hold one of the two buttons until the previously selected parameter (15) is displayed.
h.
The system will automatically exit programming mode 10 seconds after the button has been pressed.