Computer Communication
Technical Handbook
019722-101 Rev. 05
83
SC-350/360
12.11 Reading Batch Quantity Value
Revision 1.xx of the protocol:
The machine sends the current batch quantity value as a 16-bit
number. If batch counting is disabled, zero is transmitted. The batch
quantity value is the temporary quantity of the machine. The message
does not affect any register.
Revision 2.xx of the protocol:
The machine sends the current batch quantity value as a 32-bit
number. If batch counting is disabled, zero is transmitted. The batch
quantity value is the temporary quantity of the machine. The message
does not affect any register.
Computer (PC)
SC-350/360
–––––––>
ESC
–––––––>
“R”
–––––––>
“L”
<–––––––
BatchLimitRegister (BLR)
<–––––––
(BLR ^ FF00
16
+ BLR ^ FF
16
) ^ FF
16
Computer (PC)
SC-350/360
–––––––>
ESC
–––––––>
“R”
–––––––>
“L”
<–––––––
BatchLimitRegister (BLR)
<–––––––
(BLR ^ FF00,0000
16
+ BLR ^ FF,0000
16
+ BLR ^ FF00
16
^ + BLR ^ FF
16
) ^ FF
16
<–––––––
ACK