DISCLAIMER 

ƒ

 

The XenoWorks BRI Analog Microinjector should only be used in a laboratory 
environment for use on animal tissues. It is not intended for use, nor should be used, in 
human experimentation, or applied to humans in any way. This is not a medical device. 

ƒ

 

Do not open or attempt to repair the instrument without expressed and explicit 
instructions from Sutter Instrument Company.  

ƒ

 

Do not allow unauthorized and or untrained operatives to use this device. 

ƒ

 

Any misuse will be the sole responsibility of the user/owner and Sutter Instruments 
assumes no implied or inferred liability for direct or consequential damages from this 
instrument if it is operated or used in any way other than for which it is designed. 

 

PRECAUTIONS AND GENERAL SAFETY INFORMATION 

ƒ

 

Please read this manual carefully before operating the instrument. 

ƒ

 

Do not operate if there is any obvious damage to any part of the instrument. 

ƒ

 

As with all microinjection devices, sharp micropipettes can fly out of their holder 
unexpectedly. Always take precautions to prevent this from happening. Never loosen the 
micropipette holder chuck when the tubing is pressurized, and never point micropipettes 
at yourself or others. Always wear safety glasses when using sharp glass micropipettes 
with pressure microinjectors. 

ƒ

 

Use this instrument only for microinjection purposes in conjunction with the procedures 
and guidelines in this manual. 

ƒ

 

This instrument is designed for use with capillary glass micropipettes with an outer 
diameter of 1mm.  Adapters for other capillary diameters are available upon request. 

ƒ

 

Please retain the original packaging for future transport of the instrument. 

ƒ

 

Some applications, such as piezo-impact microinjection call for the use of mercury in the 
micropipette tip. The use of any hazardous materials with any XenoWorks instrument is 
not recommended and under taken at the users’ own risk. 

ƒ

 

This instrument has moving parts that may create pinch points. Take extra care not to 
operate the instrument when there is a danger of crushing fingers or cables. 

ƒ

 

Always transport the instrument in its original foam packaging. 

ƒ

 

This instrument contains no user-serviceable components. This instrument should be 
serviced and repaired only by Sutter Instrument or an authorized Sutter Instrument 
servicing agent. 

ƒ

 

Operate this instrument only according to the instructions included in this manual. 

ƒ

 

This device is intended only for research purposes. 

ƒ

 

Sutter Instrument reserves the right to change specifications without prior notice. 

ƒ

 

For technical assistance, please contact your local Sutter Instrument dealer or (in the 
U.S.) call 1-415-883-0128. You may also E-mail your queries to [email protected]

XENOWORKS ANALOG MICROINJECTOR OPERATION MANUAL – REV. 4

Summary of Contents for XenoWorks BRI

Page 1: ...XenoWorks BRI Analog Microinjector OPERATION MANUAL Rev 4 00 20100521 One Digital Drive Novato CA 94949 Voice 415 883 0128 Web www sutter com Fax 415 883 0572 Email info sutter com...

Page 2: ...ENOWORKS ANALOG MICROINJECTOR OPERATION MANUAL REV ii 4 00 20100521 Q Copyright 2008 2010 Sutter Instrument Company All Rights Reserved XenoWorks is a registered trademark of Sutter Instrument Company...

Page 3: ......

Page 4: ......

Page 5: ...h pressure microinjectors Use this instrument only for microinjection purposes in conjunction with the procedures and guidelines in this manual This instrument is designed for use with capillary glass...

Page 6: ...00 20100521 iv This page intentionally left blank XENOWORKS ANALOG MICROINJECTOR OPERATION MANUAL REV 4...

Page 7: ...4 Maintenance 11 4 1 Fitting New O rings 11 4 2 Troubleshooting 11 Appendix A Limited Warranty 13 Appendix B Accessories and Spare Parts 15 Appendix C Technical Specifications 17 Index 19 TABLE OF FIG...

Page 8: ...XENOWORKS ANALOG MICROINJECTOR OPERATION MANUAL REV vi 4 00 20100521 This page intentionally left blank...

Page 9: ...e the Figure 1 1 to identify the parts listed If any items are missing or damaged contact Sutter Instrument immediately Figure 1 1 Components of the XenoWorks analog microinjector NOTE To operate the...

Page 10: ...inge plunger that it grips in and out of the syringe barrel The sliding block is moved by rotation of the micrometer screw which can be seen running the length of the inside body of the microinjector...

Page 11: ...E UNIT 1 2 5 Angle Adjustment This knob is used to fix the microinjector at an angle appropriate for comfortable use 1 3 Micropipette Holder The micropipette holder is attached via a length of tubing...

Page 12: ...XENOWORKS ANALOG MICROINJECTOR OPERATION MANUAL REV 4 00 20100521 4 This page intentionally left blank...

Page 13: ...the ferrule is pointing in the correct direction Figure 2 1 Attaching the tubing to the injector 3 Unpack the syringe and ensure the plunger is pushed all the way in NOTE If you have decided to use t...

Page 14: ...e Volume Maximum Tubing Length 1000 l 1930 mm 500 l 965 mm 100 l 178 mm Figure 2 2 Connecting the tubing to the tip of the syringe 8 Once the hydraulic fluid has been pushed to the very tip of the tub...

Page 15: ...lamp screw until the syringe barrel is held securely Next tighten the plunger clamp screw Take care to tighten the black syringe barrel clamp first before tightening the silver plunger screw CAUTION T...

Page 16: ...the pipette holder 12 Adjust the tilt of the microinjector using the angle adjustment knob to achieve a comfortable angle for working and place the unit on the bench top by the micromanipulator Your X...

Page 17: ...ad of a fluid in the microinjector skip Step 1 1 First remove the clear chuck from the front of the micropipette and turn the injector s coarse control clockwise to advance the hydraulic fluid to the...

Page 18: ...XENOWORKS ANALOG MICROINJECTOR OPERATION MANUAL REV 10 4 00 20100521 This page intentionally left blank...

Page 19: ...s in the chuck are damaged Replace the O rings 2 There is an air bubble in the hydraulic fluid Refill the system with hydraulic fluid taking care not to introduce air bubbles There is poor control by...

Page 20: ...XENOWORKS ANALOG MICROINJECTOR OPERATION MANUAL REV 12 4 00 20100521 This page intentionally left blank...

Page 21: ...trument has been operated in accordance with the instructions outlined in the instruction manual Abuse misuse or unauthorized repairs will void this warranty Limited warranty work will be performed on...

Page 22: ...XENOWORKS ANALOG MICROINJECTOR OPERATION MANUAL REV 1 4 00 20100521 4 This page intentionally left blank...

Page 23: ...0 l Syringe V001184 250 l Syringe V001185 500 l Syringe V001186 1 000 l Syringe BR MH Micropipette holder includes micropipette holder body 9 O rings BR AT Analog tubing kit includes 2 x 1 m ETFE tubi...

Page 24: ...XENOWORKS ANALOG MICROINJECTOR OPERATION MANUAL REV 1 4 00 20100521 6 This page intentionally left blank...

Page 25: ...y Prime Tech Burleigh Storage Environment Temperature 0 70 C 32 158 F Humidity 0 95 non condensing Operating Environment Temperature 3 5 35 C 38 3 95 F Humidity 0 80 non condensing Size without syring...

Page 26: ...XENOWORKS ANALOG MICROINJECTOR OPERATION MANUAL REV 18 4 00 20100521 This page intentionally left blank...

Page 27: ...block 2 Syringe clamp 2 D disclaimer iii G General Safety Information iii I Installation and assembly 5 M Maintenance 11 Fitting new O rings 11 N notes user 20 O Operating Instructions 9 Fitting a mic...

Page 28: ...00 20100521 20 NOTES XENOWORKS ANALOG MICROINJECTOR OPERATION MANUAL REV 4...