10 Sensor signal outputs
10.3 Modbus output
Communication parameters (Modbus RTU)
Baud rate
: 19200
Device address
: Last digits of serial number
Framing / parity / stop
bit
: 8, N, 1
Response time
: 1 second
Response delay
: 0 ms
Inter-frame spacing
: 7 char
Communication parameters (Modbus TCP)
DHCP
: Yes
MAC
: Set ex-factory
IP address
: Dynamic or Static
Subnet
: Dynamic or Static
Gateway
: Dynamic or Static
Timeout
: >= 200 ms
Remarks:
•
Modbus output settings can be changed using the S4C-FS Android
service app or the optional sensor display.
•
In the Modbus TCP mode, a slave device does not support
concurrent connections because it can respond to only one polling
message at a time.
Holding register (Modbus RTU and Modbus TCP)
Channel description Resolution
Format
Length
Register
address
Flow
0.1
FLOAT
4-Byte
6
Consumption
1
UNIT32
4-Byte
8
30