4. Technical data
4. Technical data
4.1 General data
Principle of
measurement
Ultrasonic leak detection
Measuring medium
Air, refrigerants and any gases
Plugs
Plug 1: 3.5 mm stereo phone jack shared by
headphone and battery charger
Plug 2: 3.5 mm stereo phone jack for sensor or
sensor cable connection
Operating frequency
40 kHz ± 2 kHz
Operating temperature 0°C ... 40°C
Operating time
About 6 hours without Laser pointer on
About 4 hours with Laser pointer on
Charging temperature
10 °C ... 45 °C
Charging time
Around 1.5 hours
Material of the detector PC + ABS
Dimensions
See dimensional drawing on the next page
Display
3 colour black-mask LCD, 10 level
Laser pointer
640 ... 660 nm wavelength
0.4.0.5 mW output power
Weight
2.5 kg (full set)
4.2 Electrical data
Power supply
Internal NiMH rechargeable battery
4.3 Performance chart
The table shows the detection distance of varicose hole diameters at
different pressures (lab environment).
Pressure / diameter
0.1 mm
0.2 mm
0.5 mm
0.5 bar
2m
2m
10m
5.0 bar
8m
14m
18m