6.3.6
Laying of Electric Wires and Cables
The electrical cables can be laid in the grooves of the upper connecting struts of the base frame.
Using commercially available covers that fit directly into the grooves, the lines can be affixed.
Figure 22 Cable guide in the groove with cover
Optionally, the electrical cables can also be laid with cable holders that are fastened in the grooves.
The cables are attached to the cable holders with cable ties.
Figure 23 Cable guide with cable holders
When laying the cables, make sure that
▪
they cannot get jammed
▪
they are not subjected to mechanical loads or stresses (tension, pressure or bending etc.)
▪
they cannot be damaged in any other way