Operation
SUSPA ELS3 HeavyDuty - Installation Instruction
Page 59
7.5
Perform Reset
A reset must be performed both during the initial start-up and upon a power failure during the
process. This is used to protect the work surface. Proceed as follows:
On the manual switch, press both direction keys simultaneously.
The workstation moves at a slow speed until the lower mechanical end stop on the lifting
elements is reached.
The controller acknowledges this reset drive with a signal tone.
The work surface can now be moved with the two direction buttons on the manual switch.
IMPORTANT
If the Height Adjustment System does not function immediately, disconnect
power from the unit and contact the authorized dealer.
IMPORTANT
Do not disassemble the system components (e.g. the electrical controller,
switches, …), except when you have been authorized by SUSPA GmbH to do so. Any attempt to
repair the system or the system components without the authorization of SUSPA GmbH will void
the warranty.
7.6
Faults and Error Indications
WARNING
Risk of hand injury due to non-observance of the danger zone
There are risks of injuries resulting from improper conduct. Never remove wedged parts or
foreign bodies with your bare hands.
Use suitable aids.