Surveillix IKS-WP8103 Quick Start Manual Download Page 2

3.

 

To open the viewer software in your 

web browser, double-click the camera, 

and then click Browse.

The first time you connect to the camera 

you will be automatically prompted to 

install a plugin to view live video.

Default Username and Password

The username and password are case 

sensitive. It is strongly recommended that 

the password be changed after the initial 

setup to prevent unauthorized access. 

Any password change will need to be 

applied to your recorder also.

Username:   

admin

 

Password:   

1234

ASSIGNING AN  

IP ADDRESS

Surveillix IP cameras default to DHCP. This 

automatically assigns an IP address to the 

camera. If no DHCP is available, the camera 

will default to a static IP of 192.168.0.250 

after four minutes. To modify the IP 

address, use the Device Search software.

1.

 

Open the Device Search application.

2.

 

Click Find Devices, and then select 

your camera. 

3.

 

Right click and click Network Setup.

CONTENTS

ETHERNET CABLE  

CONNECTIONS

Connect a network cable to the camera 

using the RJ45 input and connect the 

other end of the cable to your network 

switch or recorder. Check the status of 

the network connection by looking at the 

link and activity LEDs. If the LEDs are 

not lit, check your network connection. 

The green link LED indicates a network 

connection and the 

orange activity LED 

flashes to indicate 

network activity.

POWER

This camera is compatible with 24vAC 

and Power over Ethernet (PoE+). Connect 

power to the camera using the provided 

power connector lead, or the terminal 

connector blocks. If you are connecting 

24vAC power, verify the polarity of the 

power connection. If you are using PoE+, 

make sure the Power Sourcing Equip-

ment (PSE) is in use in the network.

CONNECTING TO THE  

IP CAMERA 

To access the camera setup menu, 

you need to install the Device Search 

software on a PC on the same network. 

To install the Device Search application 

on your PC, download the program from 

toshibasecurity.com, and follow the 

prompts.

1.

 

Open Device Search, and click Find 

Devices.

2.

 

Locate your camera on the list.

NOTE     

If you are connecting the camera 

directly to a recorder, a crossover cable 

is necessary for most configurations.

Alarm I/O Connection

1 2

4

3

5 6 7 8 9 10 11 12

1

Alarm Out NO 1

7

Alarm Out 

COM 2

2

Alarm Out NC 1

8

GND

3

Alarm Out COM 1

9

Alarm In 4

4

GND

10

Alarm In 3

5

Alarm Out NO 2

11

Alarm In 2

6

Alarm Out NC 2

12

Alarm In 1

Audio I/O Connection

1

Audio Out

2

GND

3

Audio In

1

2

3

Hard Ceiling Mount

IKS-WP8103 IP 

PTZ Camera

Security Torx

Tool

M3 Standard Screw

M3 Security Screw

M5 Standard Screw

M5 Security Screw

IKS-WP8103 Indoor Acccessories

IKS-WP8203R Outdoor Acccessories

Waterproof Gasket

Lubricant for 

Gasket

TIP     

Static IP is the recommended default. 

4.

 

Select Static IP and type the new 

IP address and other network 

information in the appropriate boxes. 

- or - Select DHCP.

5.

 

Click Apply.

6.

 

Click OK to acknowledge the 

change.

IKS-WP8203R IP 

PTZ Camera

M4 Screws (x5)

with Anchors

Power Connection

1

AC24V 1

2

GND

3

AC24V 2

1

2

3

To power the camera, connect the 

24vAC adaptor to the power connector 

on the camera. Alternatively, users can 

use PoE to power the camera if a PoE 

switch is available. 

NOTE     

Use of the camera heater requires 

24vAC power.

Pendant Mount

Pendant Mount

NOTE     

ActiveX controller is for use with Internet 

Explorer only. Use the QuickTime plugin 

with other web browsers.