5
Cleaning and Replacing filters
Replacing UV Lamp
Reinstating
Clean the plasma dust collector
Cleaning and maintenance of the plasma dust collector
● Use mild detergent to clean
● Use a scouring pad or toothbrush to clean the
dust collector
● Achieve better result with warm water
● The HEPA/Carbon Filter will collect a large amount of dust. You may use a soft brush to clean off larger particulate on the surface
of the filter to extend useful filter life. Under typical conditions, the filter should be replaced once a year, or when very dirty (dark
gray in color).
● The germicidal UV lamp should be replaced once every 12 months. Turn off and unplug the air purifier before gently removing the
UV lamp.
● If it is hard to eliminate all dirt, presoak with diluted detergent and then use a toothbrush
to scrub.
ř
Please beware not to damage any wiring when cleaning the dust collector. In case if any
electrical discharge wire is broken, the device will lose part of or all of its dust collecting
function
ř
Any broken wire should be thrown away instead of being left inside the unit. Otherwise,
short-circuit or high-voltage spark would be resulted. Also, the circuit control of the device
would be affected.
ř
Please contact the distributor for additional electrical discharge wire
ř
Please do not clean using acidic or alkaline detergent that can create rust on the surface
of device
Thorough clean and dry
ř
After cleaning, please completely dry the unit before use. Otherwise, it could cause
electrical shock or malfunction
ř
If the front cover of the plasma dust collector is not properly installed, no electricity will be
connected
ř
Please make sure the plastic wrap for the electrical discharge wire is located at its proper
position.
1. 1 After cleaning and drying every part, then install the unit. Put every part back together with the same steps but with opposite
sequence.
2. There’s metal electrode at the bottom of the plasma dust collect, please make sure to install at its proper position. Otherwise, the
device cannot be energized.
3. There’s safeguard protective switch designed for this device, please make sure to install front cover properly. Otherwise, the
device cannot be energized.
Plasma Dust Collector
Electrical Discharge Wire
Plastic Wrap
XJ-2800(E)IM.indd 6
XJ-2800(E)IM.indd 6
2008-3-5 10:07:40
2008-3-5 10:07:40