background image

5

Cleaning and Replacing filters

Replacing UV Lamp

Reinstating

Clean the plasma dust collector

Cleaning and maintenance of the plasma dust collector

●  Use mild detergent to clean 

●  Use a scouring pad or toothbrush to clean the 

dust collector

●  Achieve better result with warm water 

●  The HEPA/Carbon Filter will collect a large amount of dust. You may use a soft brush to clean off larger particulate on the surface 

of the filter to extend useful filter life. Under typical conditions, the filter should be replaced once a year, or when very dirty (dark 
gray in color).

●  The germicidal UV lamp should be replaced once every 12 months. Turn off and unplug the air purifier before gently removing the 

UV lamp.

●  If it is hard to eliminate all dirt, presoak with diluted detergent and then use a toothbrush 

to scrub.

ř

 Please beware not to damage any wiring when cleaning the dust collector. In case if any 

electrical discharge wire is broken, the device will lose part of or all of its dust collecting 
function

ř

  Any broken wire should be thrown away instead of being left inside the unit. Otherwise, 

short-circuit or high-voltage spark would be resulted. Also, the circuit control of the device 
would be affected.

ř

 Please contact the distributor for additional electrical discharge wire

ř

 Please do not clean using acidic or alkaline detergent that can create rust on the surface 

of device

Thorough clean and dry

ř

  After cleaning, please completely dry the unit before use. Otherwise, it could cause 

electrical shock or malfunction

ř

 If the front cover of the plasma dust collector is not properly installed, no electricity will be 

connected

ř

 Please make sure the plastic wrap for the electrical discharge wire is located at its proper 

position.

1. 1 After cleaning and drying every part, then install the unit. Put every part back together with the same steps but with opposite 

sequence.

2.  There’s metal electrode at the bottom of the plasma dust collect, please make sure to install at its proper position. Otherwise, the 

device cannot be energized. 

3.  There’s safeguard protective switch designed for this device, please make sure to install front cover properly. Otherwise, the 

device cannot be energized.

Plasma Dust Collector

Electrical Discharge Wire

Plastic Wrap

XJ-2800(E)IM.indd   6

XJ-2800(E)IM.indd   6

2008-3-5   10:07:40

2008-3-5   10:07:40

Summary of Contents for Multi-Tech 2000

Page 1: ...ma Dust Collector Germ Killing UV Lamp to Destroy Micro Organisms Ionizer to Neutralize Dust Bacteria Activated Carbon Filter for Chemicals Odors Three Levels of Air Flow and Timer Controls Energy Conserving Electronic Design 2000 Multi Tech XJ 2800 E IM indd 1 XJ 2800 E IM indd 1 2008 3 5 10 06 57 2008 3 5 10 06 57 ...

Page 2: ...DO NOT UNPLUG ELECTRIC PLUG UNPLUG ELECTRIC PLUG ATTENTION ATTENTION ATTENTION ATTENTION To prevent interference and distortion it should be placed at least 1 meter away from computer television or radio ATTENTION ATTENTION Please turn off all the control switches before unplug the machine from electricity socket If the supply cord is damaged it must be replaced by the manufacturer its service age...

Page 3: ...HR Whole Unit Front View control panel air outlet air inlet Control Panel power switch ion and UV switch air flow indicator light timer indicator light power indicator light ion and UV indicator light air flow choice switch timer switch XJ 2800 E IM indd 3 XJ 2800 E IM indd 3 2008 3 5 10 07 31 2008 3 5 10 07 31 ...

Page 4: ... HR Identification of Parts Whole Unit Back View Handle Air outlet Front cover Pre filter Plasma Dust Collector HEPA Activated Carbon Filter Protective switch UV lights XJ 2800 E IM indd 4 XJ 2800 E IM indd 4 2008 3 5 10 07 33 2008 3 5 10 07 33 ...

Page 5: ... and also the place that the children can not reach Plug into a proper socket Press the POWER ON OFF button The device starts operating Press POWER ON OFF again and the device will stop working This device has three different fan modes to choose from Please choose a proper level of circulation according to indoor air quality and room size As you press FLOW the LED will show the current fan speed Y...

Page 6: ...side the unit Otherwise short circuit or high voltage spark would be resulted Also the circuit control of the device would be affected ř Please contact the distributor for additional electrical discharge wire ř Please do not clean using acidic or alkaline detergent that can create rust on the surface of device Thorough clean and dry ř After cleaning please completely dry the unit before use Otherw...

Page 7: ...ust collector or the front cover is not properly installed In case of any malfunction contact your distributor or send to local maintenance center After Service TECHNICAL SPECIFICATION Rated voltage AC100 120V 50 60Hz Dust removal rate 0 3micro80 1micro99 97 Power consumption 45W Noise level dB Low25 Med35 High45 Activated Oxygen Output 0 001ppm Dimensions in 11 8 x 7 6 x 12 4 Weight 7 25 lbs XJ 2...

Page 8: ...XJ 2800 E IM indd 8 XJ 2800 E IM indd 8 2008 3 5 10 07 46 2008 3 5 10 07 46 ...

Reviews: