background image

Troubleshooting 

14

BEFORE CALLING CUSTOMER SERVICE

If the heater does not function properly, use the following checklist.

 And this condition exists:              

Pilot won't light

NOTE: Heater operates at 

reduced efficiency below 

40  and 5  .

Cylinder valve is closed

Open  valve

Blockage in orifice or pilot tube Clean or replace orifice or pilot tube
Air in gas line

Open gas line and bleed it  (pressing 

control knob in) for not more than 1-2 

minutes or until you smell gas

Low gas pressure with cylinder 

valve fully open

Turn cylinder valve OFF and replace 

cylinder

Igniter fails

Use match to light pilot; obtain new 

igniter and replace

Pilot won't stay lit

Dirt built up around pilot

Clean dirt from around pilot

Connection between gas valve 

and pilot assembly is loose

Tighten connection and perform leak 

check

Thermocouple is not operating 

correctly

Replace thermocouple

Burmer won't light

Gas pressure is low

Turn cylinder valve OFF and replace 

cylinder 

Blockage in orifice

Clear blockage

Control  knob  is  not  in  ON 

position

Turn control knob to ON

Burner flame is low

Gas pressure is low

Turn cylinder valve OFF and replace 

cylinder

Outdoor  temperature  is  less 

than 40 

 

 and tank is less 

than 1/4 full

Use a full cylinder

Supply hose is bent or kinked Straighten hose
Control knob fully On

Check  burner  and  orifices  for 

blockage

Carbon build-up

Dirt  or  film  on  reflector  and 

burner screen

Clean reflector and burner screen

Thick black smoke

Blockage in burner

Remove blockage and clean burner 

inside and outside

If the problem is:         

Then do this:                 

Summary of Contents for SF35PHSSLP

Page 1: ...between 8 00 AM and 5 00 PM Eastern time Monday through Friday or email us at saleshelp sureheat com YOUR SAFETY 1 Read this Manual before attempting to assemble or operate your heater 2 Follow safety instructions 3 Check for leaks according to the directions in this Manual before operating your heater even if purchasing an assembled heater 4 Keep this Manual for future reference 5 Contact 1 800 2...

Page 2: ...ral Safety Instructions Components Hardware Assembly Process Gas Requirement Pre Operation Leak Testing Operation Care Maintenance Troubleshooting Warranty Table of Contents 3 5 6 7 8 8 10 11 12 13 14 15 2 ...

Page 3: ...used extensively throughout this manual Always heed these precautions as they are essential when using any mechanical or fueled equipment RECOGNIZE SAFETY SYMBOLS WORDS AND LABELS WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury NOTE indicates an important piece of information that needs to be observed to ensure the proper operation o...

Page 4: ...ulating air passageway of the appliance be kept clean FOR YOUR SAFETY If you smell gas 1 Shut off gas to the appliance 2 Extinguish open flame 3 If odor continues immediately call your gas supplier and local Fire Dept WARNING CALIFORNIA PROPOSITION 65 WARNING The burning of gas cooking fuels generates some by products which are on the list of substances which are known by the State of California t...

Page 5: ...used in compliance with local ordinances and codes or with ANSI NFPA 58 Turn off propane when not in use DANGER EXPLOSION FIRE HAZARD Never store propane near high heat open flames pilot lights direct sunlight other ignition souces or where temperatures exceed 120 49 Propane vapors are heavier than air and can accumulate in low places If you smell gas leave the area immediately Never install or re...

Page 6: ...2 Reflector 3 Washer 4 Emitter 5 Wire guard 6 Access panel 7 Base 8 Cast iron ring weight 9 M6x20 bolts 4 pcs 10 3 16 Stainless bolts 4 pcs and washers 4 pcs 11 Post with burner assembly 12 3 16 Stainless bolts 4 pcs 13 M5x10 bolt and washer 1pc 14 Propane Cylinder housing ...

Page 7: ...o base using four bolts Step 1 Attach post onto housing using four bolts and washers Keep the access panel open Step 3 Attach emmitter assembly to post using four bolts and washers Step 4 Insert ends of wire guard into holes in the post flange ...

Page 8: ... bolts then attach reflector to emitter assembly using three cap nuts Step 6 Rotate regulator toward opening in housing Line up threads on gas cylinder with those on the regulator Insert and rotate cylinder clockwise until tight Step 7 Close access panel ...

Page 9: ...must be constructed and marked in accordance with the specifications for L P gas cylinders of the U S Department of Transportation DOT or the National Standard of Canada CAN CAS B339 Cylinders Spheres and Tubes for the Transportation of Dangerous Goods and Commission L P TANK USE When not in use gas supply cylinder valve is to be in the OFF position The tank supply system must be stored upright to...

Page 10: ... and repeat steps 1 3 3 Wash off soapy solution with cold water and towel dry Check all gas supply fittings before each use and each time the gas supply cylinder is connected to the regulator Have a qualified service technician leak test the heater any time a part of the gas system is replaced Also it is recommended to perform a leak test at least once a year whether or not the L P gas supply cyli...

Page 11: ... the air in the line This can take up to 10 seconds 9 To start the burner rotate the Control Knob in a clockwise direction and stop at the desired temperature position 11 BEFORE TURNING GAS SUPPLY ON 1 Your heater was designed and approved for outdoor use only Do NOT use it inside a building garage or any other enclosed area 2 Make sure surrounding areas are free of combustible materials gasoline ...

Page 12: ...off but the pilot light will remain on 2 To turn off the pilot light depress the control knob and rotate to the OFF position WARNING FOR YOUR SAFETY Heater will be hot after use Handle with extreme care Note If pilot fails to remain lit all valves should be closed and wait at least 5 minutes before attempting to light If you experience any ignition problem please consult the Troubleshooting sectio...

Page 13: ...erous condition which can cause a fire to occur behind the valve panel thereby damaging the heater and making it unsafe to operate We recommend you check the heater and remove any spiders insects and webs at least once a year to reduce this risk Carbon deposits may create a fire hazard Clean dome and burner screen with warm soapy water if any carbon deposits develop Note In a salt air environment ...

Page 14: ...ot Clean dirt from around pilot Connection between gas valve and pilot assembly is loose Tighten connection and perform leak check Thermocouple is not operating correctly Replace thermocouple Burmer won t light Gas pressure is low Turn cylinder valve OFF and replace cylinder Blockage in orifice Clear blockage Control knob is not in ON position Turn control knob to ON Burner flame is low Gas pressu...

Page 15: ...duct to temperatures above its rated specifications which can cause considerable warping disassembly including removal of the product from a built in installation damage resulting from accident alteration misuse abuse hostile environments or improper installation repair or alteration acts of God such as fire flood hurricanes and tornadoes gas cylinders propane tanks or other fuel delivery systems ...

Reviews: